Sources, Types and Characteristics of Petrochemical Industry Wastewater
Overview
The petrochemical industry uses petroleum or natural gas as its main raw materials and, through different production processes and processing methods, produces various petroleum products, organic chemical raw materials, chemical fibers and fertilizers. Because the raw materials, process technologies and processing methods differ, the sources, types and characteristics of the wastewater generated also differ greatly. This article describes the wastewater generated by four sectors: petroleum refining, petrochemicals, chemical fibers and fertilizers.
1. Petroleum Refining Wastewater
Petroleum refining separates crude oil into different products by physical separation or chemical reaction according to boiling point. Water injection, steam stripping, condensation, water washing and oil-tank water drawing in the refining process are the main wastewater sources; wastewater also comes from auxiliary facilities such as laboratories, power stations, air-compressor stations and circulating-water systems, and from domestic facilities such as canteens and offices. By water-quality characteristics, the wastewater is classified as follows:
Oily wastewater. The largest wastewater stream in refining and oil storage/transport. It mainly contains crude oil, product oils, lubricating oils and small amounts of organic solvents and catalysts. The oil exists as floating, dispersed, emulsified and dissolved oil. Sources include condensate water, oil-gas condensate, oil/gas water washing water, oil-pump shaft seals, tank water drawing, equipment washing water and laboratory drainage.
Sulfurous (sour) wastewater. Mainly from the overhead oil-water separators of secondary conversion units (catalytic cracking, catalytic pyrolysis, coking, hydrocracking), rich-gas washing, LPG washing, LPG tank water drawing and reformed-gasoline washing. The volume is small but the pollutant concentration is high: besides large amounts of sulfides and nitrogen, it contains phenols, cyanides and oil, has a strong foul odor and is corrosive to equipment. At low pH, sulfides decompose and release hydrogen sulfide. This wastewater should not be discharged directly to the central treatment plant but pre-treated by steam stripping.
Alkaline wastewater. From the post-caustic water washes of diesel, aviation kerosene and gasoline in atmospheric-vacuum distillation and catalytic cracking units, and from LPG caustic washing. It contains free caustic soda, petroleum substances and small amounts of sulfides.
Salty wastewater. Mainly from crude-oil electric desalting tank drainage and production of naphthenates. It has high salt and oil content and other impurities, is severely emulsified and difficult to treat.
Phenolic wastewater. Mainly from atmospheric-vacuum distillation, catalytic cracking, delayed coking, electric refining and polymerization units. The wastewater from the overhead separator of the catalytic cracking fractionator contains very high phenol concentrations - more than half of the total phenol discharged by a refinery - while other units discharge lower concentrations but larger volumes. Without treatment it causes extensive pollution and seriously affects human health, crops and natural water bodies.
Non-polluted production wastewater. From circulating-water system blowdown, boiler blowdown, oil spray cooling water and unpolluted ground rainwater. It is barely polluted, with COD generally below 60 mg/L, meeting national or local discharge standards.
Domestic sewage. From auxiliary living facilities such as office toilets and canteens; usually sent to the wastewater treatment plant for unified treatment.
2. Petrochemical Wastewater
Petrochemical production uses petroleum products, petrochemical intermediates and chemical products as raw materials. The raw materials are diverse - gaseous, liquid, solid or aqueous solutions - and the processes include dissolution/extraction, oxidation, polymerization, distillation, washing, separation, absorption and drying, all of which contact water and pollute it. Additional sources are central laboratories, power stations and domestic facilities.
Petrochemical wastewater is very complex in composition: besides oil, sulfides and phenols, it contains benzene, alcohols, ethers, aldehydes, ketones, organic phosphorus, metal salts, spent catalysts, additives, reaction residues and waste materials. Organic concentration is high and much of the content is toxic or hazardous. Flow and pH vary greatly and shock loads are frequent. By quality it can be divided into oily, organic, chlor-alkali, acidic, production wastewater and domestic sewage. Main units and their wastewater constituents:
Ethylene units: wastewater from waste-heat boilers, steam generators, the water-wash section of caustic towers, equipment cleaning and floor washing; mainly acidic water, sulfurous water and spent caustic. Discharge volume and composition depend on pollution-source management; poor management and unstable operation greatly increase pollutant loss, so equipment anti-corrosion is important to avoid abnormal wastewater from acid/alkali corrosion.
Aromatic units (benzene, toluene, xylene): condensate and washing water containing benzene, toluene and xylene.
Phthalic anhydride units: wastewater from the water absorption tower containing phthalic anhydride, maleic anhydride, naphthoquinone and phthalic acid; after repeated absorption the acid content rises, the liquor turns purple-red and has a strong irritant odor.
Alkylbenzene units: pollution sources are mainly the neutralization pond and tar oil separator; wastewater contains petroleum substances and fluorides.
High-pressure (low-density) polyethylene units: extruder water, steam condensate and overflow; small amounts of polyethylene granules and oil.
Low-density polyethylene units: oil-water separator drainage, small volume but complex composition, containing titanium, aluminum, magnesium, chlorine and residues.
Polypropylene units: solid-discharge and pelletizing water; contains methanol, sodium hydroxide, sodium chloride, surfactants, isotactic and atactic polymers and catalyst residues.
Vinyl chloride units: washing settlers, wastewater stripping towers, caustic neutralizers; pollutants include chlorine, ethane, salts and alkalis; with process improvements, direct-chlorination wastewater can be eliminated.
PVC units: washing towers, strippers, gas-holder drainage and centrifugal mother-liquor settling; contains vinyl chloride monomer and mercury.
Styrene units: dilution-steam condensate from the dehydrogenation section, steam-ejector condensate and oil-water separator drainage; pollutants are toluene, ethylbenzene and styrene.
Polystyrene units: aromatic steam condensate from polymerization kettles, washing and dewatering drainage; contains styrene, benzene, ethylbenzene, magnesium sulfate and COD.
ABS resin units: material washing, coagulation and cleaning water in the post-treatment process; large volume, complex composition, often emulsified.
Epoxy resin units: from bisphenol reaction kettles, toluene kettles and condensation kettles; contains toluene, bisphenol A and phenol; resin washing water contains benzene and salts.
Cis-polybutadiene rubber units: waste-oil storage tanks, cutting/dehydration towers and butadiene recovery reflux tanks; contains oil and butadiene.
SBR (styrene-butadiene) rubber units: styrene settling and recovery tanks and extrusion dryers; contains styrene and suspended solids.
Neoprene (polychloroprene) units: chain-breaking tanks; contains butadiene, dichloroethylene, vinyl acetylene, divinyl acetylene and low-molecular substances.
NBR (nitrile rubber) units: acrylonitrile distillation columns; contains acrylonitrile, dispersants and COD.
3. Chemical Fiber Wastewater
The chemical fiber industry uses petroleum products and natural gas to produce polyester, polyamide, caprolactam, nylon-66 salt and acrylonitrile, etc. Polluted wastewater arises from reaction, distillation, condensation, washing and adsorption-separation processes, plus auxiliary and domestic facilities. Besides small amounts of oil, sulfides and phenols, it contains high concentrations of organics such as PTA, acrylonitrile, alcohols, esters, aldehydes, aromatics, organic and inorganic acids, waste polymers and heavy metals. pH varies widely and shock loads are common. Main units and wastewater constituents:
p-Xylene units: from isomerization washing/alkali towers and adsorption-separation feed filters; contains p-diethylbenzene, sodium chloride, oil, sulfur, phenol and COD; intermittent discharge.
PTA (low-temperature oxidation): from mist separators, catalyst make-up reflux tanks and scrubbers; contains acetic acid, methyl acetate and organics.
PTA (high-temperature oxidation): from waste-gas scrubbing, solvent recovery and process drainage; quality is fairly stable, but caustic wash and shutdown drainage varies greatly. Main pollutants are four acetic-acid-based solvents and four p-xylene-based aromatic carboxylic acids; PTA discharge is large, raising COD.
DMT units: from separation-tank storage and stripper separators; contains methyl acetate, methanol and formaldehyde with high COD; high-strength wastewater and residues are now comprehensively utilized, greatly reducing pollutant loss.
Polyester units: condensate from ethylene-glycol scrubbers, EG recovery column tops and residue-treatment steam ejectors.
Polyester (direct esterification): esterification drainage and EG recovery drainage containing ethylene glycol and organics; vacuum polymerization condensate is large in volume.
Acrylonitrile units: ammonium sulfate wastewater from the reaction system, recovery wastewater and CN-bearing condensate; cyanide and COD are very high.
Polyacrylonitrile units: mainly from vacuum liquid seals, large volume, high acrylonitrile and isopropanol content.
Acetone cyanohydrin units: filter water and wash water; small volume but about 5% nitrile content.
Vinyl acetate units: from the bottom of rectification columns in refining; small volume; contains methyl acetate, vinyl acetate, acetaldehyde and propionaldehyde.
Polyvinyl alcohol units: from recovery-section column bottoms; contains methyl acetate, acetaldehyde, methanol and vinyl acetate.
Caprolactam units: from extraction and flash columns; caprolactam concentration can reach tens of thousands of mg/L.
Cyclohexanol/cyclohexanone units: mixed organic waste acid from light-ends columns and salt-bearing organic waste from acid-water decanters; contains cyclohexane and tert-butanol with high mono-/di-carboxylic acid content; oil-bearing wastewater from tanks contains chromate, cyclohexane and tert-butanol.
Adipic acid units: washing-water tank and filter waste liquor and acid water; receivers and coolers discharge water containing adipic and acetic acid in large volume; circulating water tanks, carbon filters and condensers discharge organics and oil.
Nylon-66 spinning units: from solvent make-up and winding, and salt make-up and polycondensation positions; contains spinning finish and nylon salts.
Adiponitrile units: organic waste from column bottoms, filters and tar, containing hexamethyleneimine and ethanol; plus oil-bearing wastewater from cooling and wastewater tanks.
Nylon-66 salt units: blowdown-tank waste containing nylon-66 salt; hot-water and condensate tanks discharge organics.
Polyester staple fiber units: pre-spinning, post-spinning and drawing wastewater containing spinning finish; spinning waste liquid contains triglycol.
Polyester filament units: finish-tank wastewater containing oil and phosphate (intermittent); quality-control equipment wastewater contains dyes (intermittent).
Acrylic spinning units: sodium thiocyanate wastewater tank (intermittent), containing 3-4% sodium sulfate.
Polypropylene spinning units: finish and non-woven latex washing; contains finish and latex; chloride-bearing wastewater comes from deionized water.
4. Fertilizer Industry Wastewater
The fertilizer industry uses petroleum products and natural gas to produce urea, ammonium sulfate, ammonium carbonate and ammonium nitrate, with synthetic ammonia as the largest product. Ammonia is synthesized from cracked hydrocarbons and air-separated nitrogen under high temperature, high pressure and catalysts; ammonia and carbon dioxide are then synthesized into urea. Fertilizer wastewater mainly comes from material loss during production, and its quality varies with the raw material: ammonia plants using light oil or natural gas discharge wastewater containing alcohols and COD; residue-oil-based plants discharge cyanide, ammonia nitrogen, carbon black, ammonia, sulfides and heavy metals; ammonium nitrate plants discharge methylamine and nitric acid; ammonium sulfate plants discharge acids. Main units:
Ammonia (oilfield gas/naphtha feed): from low-temperature shift separators, CO2 saturators and condensate separators; contains oil, ammonia, methanol, diethanolamine and glycine.
Ammonia (residue-oil feed): from carbon-black recovery, methanol washing and pump/tank cooling; contains cyanide, ammonia nitrogen, nickel, methanol and oil.
Ammonia (oilfield gas feed): from CO2 water-drawing tanks and sour-water tanks; contains methanol, ammonia and small amounts of oil, sulfur and phenols.
Urea units: from the desorption tower, crystallization cooling and pump cooling; contains ammonia, urea and small amounts of oil.
Ammonium nitrate units: from evaporator condensate neutralizers, safety water seals, oil boiling devices, ammonia filters and ammonia separators; contains ammonia, cyanide and oil.