Key Knowledge Points for WWTP Commissioning, Operation and Maintenance Management
1. Effluent Quality
1.1 Factors Affecting Organic Matter Removal
(1) Nutrients. In ordinary sewage, nutrients such as nitrogen and phosphorus are usually available in excess of microbial needs. However, when industrial wastewater accounts for a large share, verify that the C:N:P ratio meets about 100:5:1. If nitrogen is deficient, ammonium salts are normally dosed; if phosphorus is deficient, phosphoric acid or phosphates are added.
(2) pH. Sewage pH is normally neutral, about 6.5–7.5. A slight pH drop may result from anaerobic fermentation in the sewer; a larger drop in the rainy season is often caused by urban acid rain, particularly prominent in combined sewer systems. Sudden, large pH swings — up or down — are usually caused by massive inflows of industrial wastewater. Adjusting pH normally requires dosing sodium hydroxide or sulfuric acid, which greatly increases treatment cost.
(3) Oil and grease. When the oil content of the sewage is high, aeration efficiency drops; without increasing aeration, treatment efficiency falls, but increasing aeration raises cost. High grease content also deteriorates the settleability of activated sludge and, in severe cases, causes sludge bulking and excessive effluent SS. For influent with high oil content, an oil-removal unit should be added in pre-treatment.
(4) Temperature. Temperature affects the activated sludge process extensively. First, it affects microbial activity — without temperature control, performance declines in cold winters. Second, it affects the separation performance of secondary clarifiers: temperature changes can induce density currents and short-circuiting; lower temperature increases sludge viscosity and reduces settleability; higher summer temperature lowers the dissolved oxygen saturation concentration, making oxygenation harder and reducing aeration efficiency, while air density also falls — maintaining the same air supply requires a larger air volume.
1.2 Ammonia Nitrogen Exceedance
Ammonia nitrogen is removed mainly by nitrification on the basis of the conventional activated sludge process, i.e., extended aeration with reduced system loading. The main causes of effluent ammonia exceedance are:
(1) Sludge loading and sludge age. Biological nitrification is a low-load process, with F/M generally 0.05–0.15 kgBOD/(kgMLVSS·d). The lower the load, the more complete nitrification and the higher the NH3-N to NO3-N conversion efficiency. Correspondingly, the SRT of a nitrifying system is generally long, because nitrifying bacteria have a long generation time: if the SRT is too short and sludge concentration low, nitrifiers cannot be cultivated. The appropriate SRT depends on temperature and other factors; for systems aiming primarily at nitrogen removal, SRT is typically 11–23 d.
(2) Return ratio. The return ratio of a nitrifying system is generally larger than in conventional activated sludge operation, because the mixed liquor already contains abundant nitrate: if the return ratio is too small, sludge stays too long in the secondary clarifier, denitrification occurs there and sludge floats. The return ratio is normally controlled at 50–100%.
(3) Hydraulic retention time. The HRT of a nitrifying aeration tank is longer than in conventional activated sludge operation — at least 8 h — because the nitrification rate is far lower than the organic removal rate, requiring longer reaction time.
(4) BOD5/TKN. TKN is the sum of organic nitrogen and ammonia nitrogen in the water; the influent BOD5/TKN ratio is an important factor for nitrification. The larger the BOD5/TKN, the smaller the fraction of nitrifying bacteria in the sludge, the lower the nitrification rate and efficiency; conversely, a smaller ratio gives higher nitrification efficiency. Operating experience of many plants shows an optimum BOD5/TKN of about 2–3.
(5) Nitrification rate. A specific process parameter of biological nitrification systems: the amount of ammonia converted per unit weight of activated sludge per day. It depends on the fraction of nitrifiers in the sludge, temperature and other factors; the typical value is 0.02 gNH3-N/(gMLVSS·d).
(6) Dissolved oxygen. Nitrifiers are obligate aerobes that cease activity without oxygen, and their oxygen uptake rate is much lower than that of organics-decomposing bacteria; without sufficient oxygen, nitrifiers cannot "compete" for the oxygen they need. Keep the DO in the aerobic zone above 2 mg/L; raise it further in special situations.
(7) Temperature. Nitrifiers are very sensitive to temperature: below 15 °C the nitrification rate drops noticeably; below 5 °C their physiological activity stops entirely. Effluent ammonia exceedance is therefore more pronounced in winter, especially at plants in northern regions.
(8) pH. Nitrifiers are very sensitive to pH; their activity peaks in the pH 8–9 range and is inhibited, tending to stop, above pH 9.6. Keep the mixed liquor pH of the nitrifying system above 7.0.
1.3 Total Nitrogen Exceedance
Biological nitrogen removal adds denitrification on top of nitrification — the microbial reduction of nitrate to nitrogen gas under anoxic conditions. The main causes of effluent TN exceedance are:
(1) Sludge loading and sludge age. Since good nitrification is the precondition of efficient, stable denitrification, a nitrogen-removal system must also run at low or ultra-low load with a long sludge age.
(2) Internal and external return ratios. The external return ratio of a denitrifying system is somewhat smaller than that of a purely nitrifying system, because most nitrogen is already removed upstream and the NH3-N concentration in the secondary clarifier is not high, so the risk of denitrification-induced sludge flotation is small. Denitrifying sludge also settles faster; provided the required return sludge concentration is met, the return ratio can be lowered to extend the sewage's residence time in the aeration tank. Well-run plants keep the external return ratio below 50%; the internal return ratio is generally controlled at 300–500%.
(3) Denitrification rate. The amount of nitrate denitrified per unit of activated sludge per day. It depends on temperature and other factors; the typical value is 0.06–0.07 gNO3-N/(gMLVSS·d).
(4) DO in the anoxic zone. Denitrification prefers the DO as low as possible — ideally zero — so denitrifiers can "dedicate themselves" to denitrification and nitrogen removal is maximized. In practice, however, holding the anoxic-zone DO below 0.5 mg/L is difficult, which affects the denitrification process and hence the effluent TN.
(5) BOD5/TKN. Since denitrifiers denitrify while decomposing organic matter, the sewage entering the anoxic zone must carry sufficient organics. In many plants the trunk network lags behind, so the influent BOD5 is below the design value while nitrogen and phosphorus are at or above design values; the carbon source cannot meet the denitrification demand, and effluent TN exceedance occurs from time to time.
(6) pH. Denitrifiers are less pH-sensitive than nitrifiers and metabolize normally between pH 6 and 9; the optimum range for biological denitrification is pH 6.5–8.0.
(7) Temperature. Denitrifiers are less temperature-sensitive than nitrifiers, but denitrification still varies with temperature: the rate rises up to a maximum at 30–35 °C, drops noticeably below 15 °C and tends to stop at 5 °C. To guarantee nitrogen removal in winter, increase the SRT, raise the sludge concentration or put more tanks into service.
1.4 TP Exceedance
Biological phosphorus removal relies on phosphate-accumulating organisms (PAOs) that release phosphorus under anaerobic conditions and take it up in excess under aerobic conditions; phosphorus leaves the system with the phosphorus-rich waste sludge. The main causes of effluent TP exceedance are:
(1) Temperature. Temperature affects biological phosphorus removal less markedly than nitrogen removal; within a reasonable range, the process runs successfully. Tests show the temperature should exceed 10 °C, because PAOs grow more slowly at low temperature.
(2) pH. At pH 6.5–8.0, the phosphorus content and uptake rate of PAOs remain stable; below pH 6.5 the uptake rate drops sharply. When pH falls suddenly, phosphorus concentration rises sharply in both aerobic and anaerobic zones — the larger the pH drop, the larger the release. This shows the release caused by a pH drop is not a physiological response of PAOs but a purely chemical "acid dissolution" effect; the larger the anaerobic release caused by a pH drop, the lower the subsequent aerobic uptake, i.e., the release is destructive and ineffective. A rising pH causes slight phosphorus uptake.
(3) Dissolved oxygen. Each milligram of molecular oxygen consumes 1.14 mg of readily biodegradable COD, inhibiting PAO growth and making the expected phosphorus removal unattainable. Keep the DO in the anaerobic zone low, favoring anaerobic fermentation to acids so that PAOs release phosphorus well; low DO also reduces the consumption of readily degradable organics so PAOs synthesize more PHB. The aerobic zone needs more DO, so PAOs can decompose stored PHB for energy and absorb soluble phosphate from the sewage into cell polyphosphate. Control the anaerobic-zone DO below 0.3 mg/L and the aerobic-zone DO above 2 mg/L to ensure smooth anaerobic release and aerobic uptake.
(4) Nitrate nitrogen in the anaerobic tank. Nitrate in the anaerobic zone consumes organic substrate and inhibits phosphorus release by PAOs, affecting subsequent aerobic uptake. Nitrate is also used by Aeromonas as an electron acceptor for denitrification, diverting it from fermentation to acids with fermentation intermediates as electron acceptors — suppressing the release/uptake capacity of PAOs and PHB synthesis. Each milligram of nitrate nitrogen consumes 2.86 mg of readily biodegradable COD and inhibits anaerobic release; control it below 1.5 mg/L.
(5) Sludge age. Because biological phosphorus removal works mainly by discharging waste sludge, the sludge age directly affects the volume of waste sludge and the phosphorus uptake: the shorter the sludge age, the better the phosphorus removal, since a shorter age increases waste sludge discharge and the phosphorus leaving the system, cutting the phosphorus in the secondary clarifier effluent. But in combined nitrogen-and-phosphorus removal processes, the sludge age must be kept long to satisfy nitrifiers and denitrifiers — the reason phosphorus removal is often unsatisfactory. For systems aimed primarily at phosphorus removal, the sludge age is controlled at 3.5–7 d.
(6) COD/TP. The type and content of organic substrate in the anaerobic zone relative to the phosphorus in the sewage is a key factor. Different organics give different anaerobic release and aerobic uptake results. Readily degradable organics of low molecular weight (e.g., volatile fatty acids) are easily used by PAOs, which hydrolyze their stored polyphosphate and release phosphorus — a strong release-inducing effect; high-molecular refractory organics induce release poorly. The more fully phosphorus is released anaerobically, the greater the aerobic uptake. PAOs also use the energy from anaerobic release to absorb low-molecular organics as the basis of survival under anaerobic conditions. An influent COD/TP above 15 is generally required for PAOs to have sufficient substrate and achieve ideal phosphorus removal.
(7) RBCOD (readily biodegradable COD). Studies show that when readily degradable carbon sources such as acetic, propionic and formic acids serve as the release substrate, the phosphorus release rate is high and independent of substrate concentration, depending only on sludge concentration and microbial composition — describable by a zero-order rate equation. Other organics must first be converted into such small readily degradable molecules before PAOs can metabolize them.
(8) Glycogen. Glycogen is a branched macromolecular polysaccharide of many glucose units and the intracellular storage form of carbohydrate. In PAOs, glycogen is formed under aerobic conditions; under anaerobic conditions it is metabolized to provide NADH as the feedstock for PHAs synthesis and energy for metabolism. Under extended aeration or over-oxidation, phosphorus removal deteriorates, because excessive aeration consumes part of the intracellular glycogen aerobically, leaving insufficient NADH for PHAs formation under anaerobic conditions.
(9) HRT. In a well-run municipal biological nitrogen-and-phosphorus removal system, phosphorus release and uptake take about 1.5–2.5 h and 2.0–3.0 h respectively. The release step appears more critical, so the anaerobic HRT deserves most attention: too short, and effective phosphorus release cannot be guaranteed — facultative acidifying bacteria in the sludge also fail to break macromolecular organics down into low-grade fatty acids that PAOs can ingest; too long is unnecessary, raising capital and operating cost with possible side effects. Release and uptake are interlinked: only PAOs that have released phosphorus fully anaerobically can take it up well aerobically, and only PAOs that take up well release excessively anaerobically — a virtuous cycle if tuned properly. Operating data from our plant show an anaerobic HRT of 1 h 15 min to 1 h 45 min and an aerobic HRT of 2 h to 3 h 10 min as appropriate.
(10) Return ratio. In the (R)A/O process, a key to phosphorus removal is letting the sludge "carry" enough dissolved oxygen from the aeration tank into the secondary clarifier, to prevent anaerobic phosphorus release there. But if sludge is not withdrawn quickly and the sludge blanket grows too thick, no amount of DO prevents anaerobic release. The return ratio of the A/O system should therefore not be too low — keep it high enough to remove sludge from the clarifier promptly. An excessively high ratio, however, increases energy consumption of the return and aeration systems and shortens the sludge's actual residence time in the aeration tank, hurting BOD5 and phosphorus removal. Balancing rapid sludge withdrawal against a low return ratio takes field tuning; R of 50–70% is generally adequate.
1.5 Suspended Solids
Whether effluent SS meets the standard depends mainly on the quality of the biological system's sludge, the settling performance of the secondary clarifier, and the appropriateness of the plant's process control. The main causes of SS exceedance in secondary clarifier effluent are:
(1) Secondary clarifier process parameters. Whether the design parameters are appropriate is a key factor. To save construction cost, many plants greatly shortened the HRT and raised the hydraulic surface loading, causing frequent sludge washout at the clarifier and SS exceedance. Where process adjustment requires a high sludge concentration in the biological tanks, the solids surface loading of the clarifier also becomes excessive, hurting effluent quality. These parameters should therefore be designed with generous margins to allow process control and adjustment. The main parameters affecting settling are the hydraulic retention time, hydraulic surface loading and solids flux.
Secondary clarifier HRT: the length of retention is a key operating parameter — only sufficient time guarantees good flocculation and high settling efficiency. An HRT of about 3–4 h is recommended.
Hydraulic surface loading: for a given inflow, a clarifier can only remove particles whose settling velocity equals or exceeds its hydraulic surface loading; the smaller the loading, the more particles removed, the higher the settling efficiency and the lower the effluent SS. A low hydraulic surface loading (0.6–1.2 m³/(m²·h)) favors effective settling of sludge and suspended solids.
Solids surface loading: the smaller the solids surface loading, the better the sludge thickening in the clarifier; an excessive loading raises the sludge blanket, and flocs leave with the effluent before settling, hurting SS. Keep it below 150 kgMLSS/(m²·d).
(2) Activated sludge quality. Sludge quality shows in four aspects: good adsorption performance, high biological activity, good settleability and good thickening performance. Colloidal pollutants must first be adsorbed onto the flocs and then onto the bacterial surfaces before being metabolized, so sludge with poor adsorption removes colloids poorly; sludge with low biological activity decomposes organics slowly. Only sludge with good settleability separates effectively from water in the clarifier — if settleability deteriorates, separation suffers, the effluent turns turbid with SS exceedance, and in severe cases massive sludge loss depletes the biomass and further impairs organics removal. Only sludge with good thickening performance yields a high waste-sludge concentration; otherwise the return ratio must rise to maintain the return flow, shortening the actual residence time in the aeration tank and undermining treatment.
(3) Influent SS/BOD5. The MLVSS fraction of the sludge correlates strongly with the influent SS/BOD5 ratio: a high ratio gives a low MLVSS fraction and vice versa. Experience shows that below SS/BOD5 of 1 the MLVSS fraction stays above 50%; above 5 the VSS fraction falls to 20–30%. With a low MLVSS fraction, the system must maintain a long sludge age to secure nitrification, sludge aging becomes evident, and effluent SS exceeds the standard.
(4) Toxic substances. Strong acids, strong alkalis or heavy metals in the influent poison the activated sludge, destroy its treatment function, and in severe cases disintegrate the sludge so it cannot settle, causing SS exceedance. The fundamental remedy is stronger management of upstream pollution sources.
(5) Temperature. As described above, temperature affects microbial activity and the separation performance of the secondary clarifier — density currents and short-circuiting under temperature swings, and reduced settleability at lower temperatures due to increased viscosity.
2. Sludge Cake Moisture Content
In China, wastewater treatment plants in service or under construction generally use the activated sludge process with a short design sludge age and essentially no sludge thickening or digestion facilities, so waste sludge volumes are large, rich in organic matter and hard to dewater. To hold the cake moisture below 80%, a large PAM dosage is needed, raising cost. For good thickening and dewatering, prepare the flocculant solution at a concentration of 0.1–0.5%: too dilute, and the dosing volume and preparation frequency grow; too concentrated, and the viscosity rises, mixing becomes uneven, the screw pump faces higher resistance, and equipment wear and line blockage accelerate. Different batches and grades of flocculant differ considerably in density, so calibrate the preparation concentration periodically as needed, adjust dosage to guarantee dewatering performance and reduce waste, and keep dry powder chemicals dry during storage and use.
3. Mechanical and Electrical Equipment
Stable operation of the sewage and sludge treatment systems also depends on the condition of the mechanical and electrical equipment matched to the process; stable, efficient equipment operation greatly influences plant energy savings.
(1) Bar Screens
The screen is the first process step and one of the most failure-prone devices in a plant; a screen failure stops plant inflow. Common problems: jamming — long contact with sewage wears the bearings and causes jamming, chain or rake misalignment and other mechanical faults; strengthen lubrication and routine inspection of the mechanical parts. Blockage — long fibers, plastic bags and other entangling debris in the sewage clog the bars and rakes; this reduces the clear screen area, raising the through-screen velocity and lowering screening efficiency, and also slows the channel, causing grit deposition and overflow. Generally resolved by technical retrofit or frequent manual cleaning.
(2) Lifting Pumps
Most plants use submersible pumps. In service, the various impurities and scum in the sewage entangle the impellers and fill the clearance of the sealing rings, degrading mechanical seals and pump efficiency, letting sewage enter the seal chamber and causing failures — in severe cases motor burnout from overcurrent. The remedies: strengthen screening upstream, inspect submersible pump insulation and seals regularly, verify pump efficiency, and rotate pumps on a schedule. Because inflow varies over 24 hours and the completeness of the sewer network differs, plant inflow can change substantially between periods — seasonal variation is very pronounced in combined systems. Submersible pump selection should therefore leave generous adjustment room: configure several pumps in a graduated capacity sequence, with fixed-speed pumps sized for the average flow and variable-speed pumps tracking flow variations, supplementing by switching pumps on or off during large fluctuations.
(3) Blowers
Blowers are the key equipment of the process and the largest energy consumers. Air volume, pressure, power consumption and noise are the basic selection parameters; match the applicable range and turndown to the process. Biological reactor fine-bubble aeration generally uses centrifugal blowers, which are efficient, long-lived, need no lubrication inside the casing and cannot contaminate the air with oil; they outperform roots blowers in air volume/pressure range, noise control and stability. Roots blowers suit shallow tanks with modest air demand. For energy control, use variable-frequency regulation and configure several blowers in a graduated volume sequence for different operating conditions, improving flexibility and reducing power draw. Clean the oil cooler and oil filter regularly to keep oil quality; replace and lab-test oil on schedule to prevent emulsification. Oil coolers are air-cooled or water-cooled: for air cooling, clean the fins regularly against blockage and dust; for water cooling, maintain the cooling tower and piping, keep circulating water quality, add corrosion/scale inhibitors periodically against bacterial growth, scaling and galvanic corrosion of copper parts. Clean or replace the intake filter regularly, keeping intake depression within the specified range to reduce surge.
(4) Aerators
Most aeration today uses fine-bubble membrane aerators — disc, dome, panel or tube types with rubber membranes. Over time, micropore clogging, rising resistance, rubber aging and loss of elasticity reduce oxygenation efficiency. Clean aerators regularly — formic acid washing or high-volume high-pressure air washing — carefully controlling acid concentration, air volume, intensity and frequency with attention to safety. Drain condensate from the aeration system regularly through the drain valves. Replace severely clogged or damaged aerators promptly to keep aeration uniform across the biological tank and prevent dead zones and sludge accumulation.
(5) Sludge Withdrawal Equipment
Some processes have no secondary clarifier — SBR, UNITANK, etc. — with flat tank bottoms that form a sludge funnel during withdrawal; later-drawn mixed liquor is dilute, insufficient sludge is removed, and the waste sludge concentration falls, raising sludge handling energy and chemical consumption. For such processes, prefer intermittent withdrawal or retrofit to multi-point withdrawal. In systems with a secondary clarifier, maintain the sludge scraper/suction machines regularly to keep withdrawal smooth and prevent sludge accumulation from affecting effluent SS.
(6) Dewatering Machines
Mechanical dewatering in China relies mainly on centrifuges and belt filter presses. For centrifuges, study the required solids content of the thickened sludge feed, the feed rate (installed capacity), maximum output, differential speed and bowl speed, and the effect of PAM type, dosage rate and dosing concentration on cake solids, filtrate SS and solids recovery. Two levers improve separation: the larger the differential speed, the shorter the sludge residence and the wetter the cake with dirtier filtrate; the smaller the differential, the longer the residence and the more complete the separation — but beware of sludge blockage. Differential speed can be auto-adjusted to compensate for feed solids variation. For a given sludge, reduce the feed rate to improve separation, or increase the flocculant dosage rate to speed up separation.
Common problems:
Start-up or vibration alarms: a low-differential alarm tripping the main motor at start-up, or heavy vibration with abnormal noise, is usually caused by incomplete rinsing at the previous shutdown — solids accumulate at the discharge end, lowering the bowl–scroll differential at restart; or irregular residues on the bowl inner wall unbalance rotation and trigger vibration alarms.
High bearing-temperature alarms: caused mainly by blocked grease lines and insufficient lubrication. The semi-automatic grease system has long, thin lines and long intervals, so single grease injections often plug them; once blocked, clear manually, and grease more frequently to keep the lines open. Do not over-grease either — too much grease also raises bearing temperature.
Main motor alarms / trips: adjusting the bowl speed too much or too quickly at start-up or during operation causes acceleration/deceleration over-voltage and a main motor alarm. Field experience shows frequency adjustments of about 2 Hz are safe. High-speed rinsing also tends to cause over-voltage, so an operator should attend the machine during high-speed rinsing.
No sludge discharged: the machine runs normally with all related equipment in order, but no cake emerges; the filtrate is turbid, differential and torque high, no abnormal noise or vibration; torque barely changes between high- and low-speed rinsing, sometimes fluctuating wildly; restart is difficult with no differential. This mostly happens in the rainy season: heavy inflow shocks the biological tank sludge load, waste sludge becomes loose and fine-grained. The smaller the floc particles, the larger their specific surface (growing exponentially), the higher their hydration strength and filtration resistance — poor flocculation and poor dewaterability. Without prompt process adjustment, the centrifuge torque falls short (too high); in constant-torque mode the differential tracks it, and once the differential is too large, residence shortens and the solid-ring layer thins; the increased relative motion between bowl and scroll agitates the liquid-ring layer, returning part of the separated solids to it and losing them with the filtrate — hence no cake. With dilute, loose sludge, run at high bowl speed, low differential and low feed: high speed raises the separation factor (the finer and lighter the particles, the higher the required separation factor), low differential extends residence, improves flocculation and centrifugal separation time, reduces agitation of the liquid ring, raising both solids recovery and cake solids; low feed further improves both.
For belt filter presses — where two tensioned belts carry the sludge layer in an S-curve through a series of rollers, pressing out capillary water by belt tension and shear — note: distribute sludge evenly in the pre-thickening zone; use soft scraper material to reduce belt and splice wear; keep belt wash-water pressure sufficient and use stainless self-cleaning nozzles to keep the belt open; maintain the auto belt-tracking and tensioning devices to reduce edge wear; ensure the control system has interlock protection against false operation.
Common problems: belt slipping — reduce the feed if overloaded, increase tension if too slack, repair or replace damaged rollers. Belt tracking off-center — even out the feed or replace the leveling device, inspect and replace locally damaged or worn rollers, check roller alignment and repair the tracking device. Severe belt clogging — lengthen rinsing or raise wash pressure, reduce excessive tension, avoid PAM overdosing (excess viscosity and undissolved PAM clog the cloth), strengthen pre-treatment against grit. Falling cake solids — correct insufficient or misprepared chemical dosage and dosing-point placement; reduce belt speed if the cake becomes too thin (keep cake thickness at 5–10 mm); increase tension if too slack for adequate pressing; stop and rinse the belt if clogged.
4. Monitoring Instruments
Because the wastewater carries many impurities in a harsh environment, online instruments often suffer large measurement errors or high failure rates, greatly weakening online monitoring and automation. High pollutant concentrations and suspended solids in the influent form scale in sampling lines and analyzer sample tubes, so configure sample pre-treatment units matched to the instruments and select analyzer ranges matched to the water quality. When procuring equipment, the control systems of large packaged units should match the plant's main control system family, or communication with the plant-wide automation will be hard or costly. Establish detailed maintenance and operating procedures: plan spare parts in advance; calibrate and correct analyzers periodically; clean piping and pre-treatment units; replace consumables and wear parts; and strengthen day-to-day management of the online monitoring system.
Because of their special structures and large open treatment areas, wastewater plants suffer frequent lightning strikes that threaten outdoor equipment. Apply class-2 and class-3 lightning protection to field equipment and instruments — skimping on these facilities to cut construction cost will cost far more later in operation and management.