Water Quality Monitoring: Sampling Design, Preservation and Key Indicators Explained
Water quality monitoring provides the data and information needed for environmental management and the basis for assessing the condition of rivers, seas and other water bodies.
1. Scope of Routine Monitoring
Routine monitoring covers surface water and groundwater. In surface water monitoring, the instruments are relatively simple, so physical indicator data are usually easy to obtain. Common physical instruments include turbidimeters for turbidity, filter photometers for color, conductivity meters for conductivity, and multi-parameter water quality monitors capable of measuring several physical indicators simultaneously.
2. Basic Data to Collect Before Setting Up Monitoring
1. Hydrological, climatic, geological and geomorphological data of the water body: variations in water level, flow volume, flow velocity and direction; rainfall, evaporation and historical flood records; river width, depth, bed structure and geology.
2. Development, industrial distribution, resource exploitation and land use in the monitored area, especially the scale and application of underground works; the area and quantity of fertilizer and pesticide application; the current status of sewage irrigation, discharge, pollution reception and surface water pollution.
3. Present status and uses of water resources along the water body: distribution of drinking water sources and key source protection zones, land functions within the basin and near-term usage plans.
4. On the basis of the above surveys, identify the main pollution sources and pollutants, and divide the groundwater into several hydrogeological units according to regional characteristics and the main groundwater types.
3. Design of Monitoring Sections and Sampling Points
(1) Based on a comprehensive analysis of the survey results and related data, monitoring sections should be laid out representatively, so that they truly and comprehensively reflect the spatial distribution and variation of water quality and pollutants; sections and sampling points are determined according to the monitoring purpose and items, taking into account manpower and resources.
(2) Sections are required upstream and downstream of major residential and industrial areas where large volumes of wastewater discharge into rivers; upstream of the confluence of major tributaries and at the point where the mixed flow is fully blended with the main stream; at the estuary of rivers entering the sea; in tidal reaches and areas of severe soil erosion; at the main inlets and outlets of lakes and reservoirs; and at the entry and exit points of international rivers crossing national borders.
For point-source pollution areas (pollutants from seepage pits, seepage wells and waste dumps in areas of low aquifer permeability), monitoring wells are placed closest to the pollution source. For belt-shaped pollution areas (seepage pits, wells and dumps in areas of high permeability, and industrial/domestic sewage discharged along rivers or canals), a grid layout of monitoring wells is appropriate. Samples are generally taken 0.3–0.5 m below the water surface.
4. Sampling Frequency
(1) For rivers: main streams of large river systems and small and medium rivers are sampled at least 6 times a year, twice each in the high-flow, low-flow and normal-flow seasons. Rivers flowing through cities or industrial districts, heavily polluted rivers and scenic waters are sampled at least 12 times a year, monthly or as conditions require.
(2) For tidal rivers: sampling covers the high-, low- and normal-flow seasons, 2 days per season, during spring and neap tides; samples should be taken at rising and falling tide on the same day and measured separately. Rising-tide samples are taken when the tide reaches its highest level at each section, falling-tide samples at lowest level; if conditions do not allow, sampling may be omitted during neap tides.
(3) For lakes and reservoirs: those with dedicated monitoring stations are sampled at least once a month (at least 12 times a year); others twice a year, once each in the low- and high-flow seasons. Lakes and reservoirs receiving wastewater and heavily polluted should be sampled more frequently as appropriate.
Sampling and monitoring methods and technology should be selected according to the nature of the monitored object, the concentration range and the measurement requirements.
5. Industrial and Municipal Wastewater Sampling Points
(1) For factories: sampling points at the workshop discharge outlets measure first-class pollutants (mercury, cadmium, arsenic, lead, hexavalent chromium, organochlorine compounds, strong carcinogens, etc.); at the plant's main discharge outlet they measure second-class pollutants (suspended solids, sulfides, volatile phenols, cyanide, organophosphorus compounds, petroleum, copper, zinc, fluorine, nitrobenzenes, anilines, etc.). For plants with treatment facilities, sampling points are set at the facility outlet; to evaluate treatment performance, points can be set at both inlet and outlet.
(2) On discharge channels, sampling points should be in straight reaches with stable flow and no upstream sewage inflow; samples are taken at 1/4–1/2 depth as representative of the average concentration.
(3) For municipal sewage (domestic sewage, hospital sewage, comprehensive discharge outlets): sampling points are set at the city's main or total discharge outlets, at different positions along the trunk sewers, at the outlets where sewage enters the water body, and at manholes where non-residential branches connect to the trunk sewer.
6. Sample Collection and Preservation
1. Separate samples are required for suspended solids, pH, dissolved oxygen, BOD, oil, sulfides, residual chlorine, radioactivity, microbiology, etc. Samples for dissolved oxygen, BOD and organic pollutants must fill the container completely; pH, dissolved oxygen and conductivity should be measured on site. Hydrometric and meteorological parameters should be recorded simultaneously with sampling.
2. Containers should be made of stable materials that do not adsorb the target components and contain few impurities — polyethylene and borosilicate glass are widely used; quartz or PTFE containers are also usable but expensive.
3. Stopper the sampler tightly, sealing with tape or paraffin if necessary; avoid loss or contamination from vibration and collision — ideally pack sample bottles in boxes with foam plastic or paper filler.
4. Each sampling period requires at least one monitoring run; drinking water is monitored twice per period, at least 10 days apart — one sample analyzed immediately, the second sampled and analyzed 10 days later — and both sets of data are reported.
7. Sample Digestion
Purpose: destroy organic matter, dissolve suspended solids, and oxidize the target elements in their various valence states into a single high valence state or into inorganic compounds that are easy to separate.
Methods: wet digestion and dry ashing. In dry ashing, an appropriate volume of sample is evaporated to dryness in a porcelain or quartz dish in a water bath, then transferred to a muffle furnace and ignited at 450–550 °C until the residue turns grayish-white and the organic matter is fully decomposed. The dish is cooled, the ash dissolved with an appropriate amount of 2% HNO3 (or HCl), filtered, and the filtrate made up to volume for measurement. Dry ashing is not suitable for samples in which volatile components (arsenic, mercury, cadmium, selenium, tin, etc.) are to be determined.
8. Key Water Quality Indicators
1. Color: a color above 15 degrees in drinking water is noticeable to most people, and above 30 degrees is objectionable; the standard requires drinking water color not to exceed 15 degrees.
2. Turbidity: an optical property expressing the clarity of water and one of the most important indicators of water quality, also a key basis for evaluating the purification efficiency of treatment equipment. A lower turbidity means fewer organics, bacteria, viruses and other microorganisms, which improves disinfection effectiveness and reduces the formation of halogenated organics.
3. Odor and taste: odor mainly arises from organic matter and may indicate increased biological activity or industrial pollution. A change in the normal odor of a public water supply may signal a change in raw water quality or insufficient treatment.
4. Residual chlorine: the chlorine remaining after a specified contact time following chlorination. Its sustained bactericidal capacity prevents self-contamination of the distribution network and safeguards supply quality.
5. Chemical oxygen demand (COD): the oxygen required by a chemical oxidant to oxidize the organic pollutants in water. A higher COD indicates more organic pollution, which mainly originates from domestic and industrial discharges and from the decay of plants and animals washed into the water.
6. Total bacterial count: bacteria in water come from air, soil, sewage, garbage and animal/plant remains, and include pathogens. The Chinese standard requires no more than 100 colonies per mL of drinking water.
7. Total coliforms: an indicator organism of fecal contamination; its detection indicates fecal pollution and its degree. If the total coliform index meets the drinking water standard after disinfection, other pathogenic bacteria have essentially been killed. The standard allows no more than 3 per liter.
9. Standard Test Methods
The analytical methods cited above follow the Standard Examination Methods for Drinking Water (GB/T 5750-2006) series — sensory and physical indicators (GB/T 5750.4), inorganic non-metallic indicators (GB/T 5750.5), metallic indicators (GB/T 5750.6), aggregate organic indicators and organic indicators (GB/T 5750.7 / 5750.8), disinfection by-product indicators (GB/T 5750.10), disinfectant indicators (GB/T 5750.11), microbiological indicators (GB/T 5750.12) and radioactivity indicators (GB/T 5750.13) — as well as the urban construction industry standards CJ/T 141–150-2001 (e.g., CJ/T 145-2001, CJ/T 148-2001) and Water Quality — Determination of Total Nitrogen by Alkaline Potassium Persulfate Digestion UV Spectrophotometry (HJ 636-2012).