Siphon Filter Beds: Meaning, Structure and Role in Water Treatment Filtration
The siphon filter is a variant of the rapid filter. Its distinguishing feature is that both the influent water and the discharge of backwash water are handled by siphons, which saves two gate valves. In addition, it uses a low-head-loss water distribution system and the water level of the filter itself to perform backwashing, without the need for a separate wash-water tank or pump. Because hydraulic operation makes automatic control of the filter relatively easy, it has found fairly wide application.
A siphon filter consists of 6–8 individual filter cells forming one integral structure. The cells are mainly rectangular, though circular layouts are possible for small flows. The central part of the filter corresponds to the pipe gallery of a conventional rapid filter; the influent water and the discharge of wash water are handled by siphons, and a vacuum control system (item 14) is installed above the pipe gallery.
During filtration, the filtered-water level is always higher than the filter media layer, so the filter operates under positive head and negative-head conditions never occur. The water level inside each cell differs according to the head loss across its media layer.
The distribution system of a siphon filter must be a low-head-loss type, so backwashing can be driven simply by the water level of the filter's own filtered water (the level in the clear-water channel).
Backwashing sequence: first, the vacuum in the influent siphon (item 3) is broken, so water from the distribution channel (item 2) stops entering the cell while filtration continues. At first the water level in the cell drops quickly, but it soon levels off — at this point backwashing can begin. The vacuum system (item 14) extracts the air from the wash-water siphon (item 15), forming a siphon that draws the standing water in the cell down to the lower part of the filter center, from where it is discharged through the wash drainage pipe (item 16). As the water level in the cell falls, once a sufficient level difference forms between the clear-water channel and the cell, the backwash formally starts. The flow path of the wash water is similar to that of a conventional rapid filter. When the media is clean, the vacuum in the wash siphon (item 15) is broken and washing stops immediately; then the influent siphon (item 3) is started again and the cell returns to filtration.
q = nQ/F (3.38)
where q — backwash intensity (L/(s·m²)); Q — filtration flow of one cell (L/s); F — area of one cell (m²).
n ≥ 3.6q/v (3.39)
where v — filtration rate (m/h).
With a backwash intensity of 10–15 L/(s·m²) and a filtration rate of 8 m/h, the formula shows that at least 5–7 cells are required. A higher filtration rate reduces the number of cells needed.
In design, many principles for the siphon filter are the same as for the conventional rapid filter and are not repeated here; the specific issues are discussed below.
Because the wash-water head is included, a siphon filter is deeper than a conventional rapid filter; siphon filters built in China are 4.5–5 m deep. Their dimensional components are as follows:
H8 — freeboard, 0.1–0.3 m;
H1 — height of the underdrain plenum at the bottom, generally 0.3 m;
H2 — height of the low-head-loss distribution system;
H3 — thickness of the media layer, determined by design requirements;
H4 — expansion height of the media during backwash, H4 = H3·e%;
H5 — total height of the wash-water troughs, H5 = clear trough height + structural bottom thickness (approx. 0.1 m);
H6 — level difference between the effluent control weir and the trough rim, i.e., the available wash-water head (1.0–1.3 m);
H7 — maximum filtration head, 1.5–2.0 m.
Total filter depth = H1 + H2 + H3 + H4 + H5 + H6 + H7 + H8 (3.40)
The available wash-water head of a siphon filter is only about 1.1–1.3 m, so the distribution system can only be a low-head-loss type. Common low-head-loss systems include double-layer perforated plates, plate-and-mesh systems, triangular-channel perforated plates, perforated filter bricks and slit-type nozzles. Small filters favor nozzles, large filters favor double-layer perforated plates.
Slit-type nozzle low-head-loss distribution systems are widely used in siphon filters, valveless filters, pressure filters and ion exchangers. Operating practice has proven reliable performance, and the gravel support layer can be omitted, reducing filter depth. The drawbacks are more complex installation and higher cost; about 40–60 nozzles are installed per square meter, each nozzle having a slit area of 100–350 mm², with the total slit area about 0.5–2% of the filter area.
Two connection methods exist between nozzle and plate: with steel or cast-iron plates, the nozzle can be screwed directly into tapped holes without a base; with reinforced-concrete plates, a short pipe embedded in a base is used and the nozzle is attached to it.
The vacuum siphon system is an essential part of the siphon filter, consisting of a vacuum pump, vacuum tank, piping (including control valves) and the influent and wash siphons.
Water ejectors can replace the vacuum pump. A vacuum tank may be provided for centralized control, or omitted — the siphon can be primed directly by the ejector or vacuum pump.
The influent and wash siphons are sized for the flow they must pass; their cross-section may be circular or rectangular, and they can be welded from steel plate or made of cast-iron pipe. The vacuum pump is selected to extract the required air volume within the planned priming time, with an appropriate margin; priming the wash siphon should take about 2–5 minutes.
The siphon filter has many advantages in process configuration, but also some drawbacks. Compared with the conventional rapid filter:
Advantages: no large gate valves or their electric/hydraulic actuators are needed; washing uses the filter's own effluent flow and head, without a wash-water tower or pump; within a certain range, filtration rates across the cells are automatically and evenly balanced as the inflow varies, with no rate-control devices; the filtered-water level is always above the media, maintaining positive head so negative head cannot occur; equipment is simple and the pipe gallery is small, with control valves and piping concentrated around the central vacuum tank — convenient to operate, easy to automate, fewer operators and lower running costs; investment is 20–30% lower than a conventional rapid filter of the same capacity, with 30–40% savings in metal materials.
Disadvantages: the structure is deeper (5–6 m); with a low-head-loss distribution system the cell area should not be too large, because the wash-water head is limited by the filter depth — at most about 1.3 m with no surplus head to adjust, so backwashing is sometimes less effective.