Solving the RO Concentrate Treatment Challenge and Driving Zero Discharge of Landfill Leachate
1. RO reverse osmosis technology
RO (Reverse Osmosis) is an efficient water treatment technology widely used for advanced treatment of industrial wastewater, seawater desalination and drinking water purification. Its core principle is the selective permeability of a semi-permeable membrane: under pressure, water molecules pass through the membrane while dissolved substances (such as salts and organics) are retained, so the water is purified and concentrated.
2. Characteristics and treatment difficulties of landfill leachate RO concentrate
Characteristics of landfill leachate RO concentrate:
Landfill leachate RO concentrate is characterised by high salinity, high COD (chemical oxygen demand), high ammonia nitrogen and a large amount of refractory organics. These features make RO concentrate one of the most difficult wastewater types to treat.
Treatment difficulties:
High salinity: a high-salinity environment inhibits microbial activity and impairs biological treatment.
High COD and refractory organics: these substances are hard to remove by conventional biological methods and require special techniques such as advanced oxidation.
High treatment cost: conventional methods such as evaporation and crystallisation consume a lot of energy and are expensive, which makes large-scale application difficult.
3. The SINOKLE solution
Process flow diagram
Equipment on site
4. Influent and effluent specifications
Concentrate influent specifications
No. | Controlled pollutant | Value | Unit | Test standard |
1 | Chemical oxygen demand (CODCr) | ≤5300 | mg/L | (HJ 828-2017) |
2 | Ammonia nitrogen | ≤70 | mg/L | (HJ 535-2009) |
3 | Total nitrogen | ≤800 | mg/L | (HJ 636-2012) |
4 | Conductivity | ≤20000 | uS/cm | Standard instrument |
5 | Colour | ≤300 | times | Standard instrument |
6 | Suspended solids | ≤100 | mg/L | (GB 11901-89) |
Concentrate effluent specifications
No. | Controlled pollutant | Value | Unit | Test standard |
1 | Chemical oxygen demand (CODCr) | ≤500 | mg/L | (HJ 828-2017) |
2 | Ammonia nitrogen | ≤50 | mg/L | (HJ 535-2009) |
3 | Total nitrogen | ≤500 | mg/L | (HJ 636-2012) |
4 | Colour | ≤40 | times | Standard instrument |
5 | Suspended solids | ≤30 | mg/L | (GB 11901-89) |
5. Treatment performance


Using CDOF for catalytic ozonation of the concentrate greatly improves the water quality indicators, as the comparison of water samples before and after treatment clearly shows. The oxidised concentrate is then returned to the biological tank of the wastewater plant, which prevents pollutants from recirculating and continuously degrading the treatment system. This not only achieves full-volume treatment but also makes plant operation more stable and sharply reduces the cost of concentrate treatment.