Wastewater Treatment Glossary: Multiple-Effect Evaporation

2026-11-16 09:43:21
立即下载

In evaporation operations the secondary vapour is produced in large quantities and carries a great deal of latent heat, so it should be recovered and reused. If the secondary vapour is led into the heating chamber of another evaporator, then as long as the operating pressure and the boiling point of the solution in that evaporator are lower than those in the original one, the incoming secondary vapour can still perform a heating duty. This mode of operation is known as multiple-effect evaporation.

Each evaporator in a multiple-effect train is called an effect. The evaporator into which live steam is introduced is the first effect; the evaporator heated by the secondary vapour from the first effect is the second effect, and so on. The purpose of using multiple-effect evaporators is to reduce the consumption of heating steam. Theoretically, 1 kg of heating steam can evaporate about 1 kg of water.

In practice, however, heat losses occur, and the latent heat of vaporisation of water in the separation chamber is greater than the latent heat of condensation in the heating chamber, so more than 1 kg of heating steam is actually needed to evaporate 1 kg of water. Experience gives the steam economy (U = W/D) as 0.91 for a single effect, 1.76 for a double effect, 2.5 for a triple effect, 3.33 for a quadruple effect and 3.71 for a quintuple effect. The growth rate of W/D therefore falls as the number of effects rises: moving from a single to a double effect saves about 50% of the heating steam, whereas moving from four to five effects saves only 10%. Moreover, as the number of effects increases, the loss of temperature difference for heat transfer grows, the production intensity of the evaporators falls sharply and the equipment cost multiplies. Beyond a certain number of effects, the steam saved by adding an effect may no longer justify the extra capital cost.

In multiple-effect evaporation, live steam is admitted to the first effect; the secondary vapour generated in the first effect serves as the heating steam for the second effect, while the heating chamber of the second effect acts as the condenser of the first effect; the secondary vapour generated in the second effect then heats the third effect, and so on. Several evaporators connected in series in this way form a multiple-effect evaporator train. Because the operating pressure of the evaporation chamber falls from effect to effect, the last effect of a production-scale multiple-effect evaporator is connected to a vacuum system. The temperature of the heating steam and the boiling point of the solution also fall in turn, while the concentration of the finished solution rises from effect to effect. The secondary vapour from the last effect passes to a condenser, where it is cooled by water and removed as condensate.

To use the available temperature difference efficiently, multiple-effect evaporation normally adopts one of the following three flow arrangements, depending on the properties of the material being processed.

Figure 1 Three-effect evaporation with forward feed

The advantages of this arrangement are that the feed liquor flows automatically into the next effect thanks to the pressure difference between adjacent effects, so no pump is needed; and because the boiling point in the preceding effect is higher than that in the following one, the liquor flashes when it enters the next effect, which evaporates part of the water as additional vapour. Operation is also relatively simple and easy to keep stable. Its main drawback is a drop in the heat-transfer coefficient, because the concentration in the downstream effects rises progressively while the boiling point falls, so the viscosity of the solution gradually increases.

Figure 2 Three-effect evaporation with backward feed

Its advantage is that the effects of concentration and of temperature on the viscosity of the solution roughly cancel each other out, so the heat-transfer conditions, and hence the heat-transfer coefficients, are much the same in every effect.

The drawbacks are that the feed liquor must be pumped and that no flashing occurs on admission. This arrangement is therefore used only where the viscosity of the solution varies strongly with temperature.

(2) Estimate the evaporation rate of each effect from experience and then calculate the concentration of the solution in each effect. The evaporation rates are usually set on the assumption that they are equal in all effects, that is:

(1) Determine the total evaporation rate from the material balance.

The quantities to be calculated in multiple-effect evaporation are the amount of water evaporated in each effect, the consumption of heating steam and the heat-transfer area. Because there are many effects, the number of unknowns is large and the calculation is far more complicated than for single-effect evaporation; electronic computers have therefore been used for the purpose since 2015. The underlying basis and principles remain the material balance, the heat balance and the heat-transfer rate equation. Since unknown parameters appear during the calculation, a trial-and-error method is normally used, in the following steps.

For forward-feed evaporation, because flashing occurs, the following ratios may be assumed

For two effects, W1 : W2 = 1 : 1.1

For three effects, W1 : W2 : W3 = 1 : 1.1 : 1.2

Once the evaporation rate of each effect has been assumed, the concentration of the finished solution from each effect can be obtained from the material balance.

(3) Assume the operating pressure of each effect in order to find the boiling point of the solution in that effect. The pressures are normally set so that the pressure drop is the same across each effect, that is, the pressure difference between two adjacent effects is

where p1 is the pressure of the heating steam, Pa;

pe is the pressure in the condenser, Pa;

(4) Use the heat balance to determine the amount of heating steam and the amount of water evaporated in each effect.

(5) Distribute the available temperature difference among the effects on the principle of equal heat-transfer area, and calculate the heat-transfer area of each effect from the heat-transfer rate equation.

(6) Check whether the heat-transfer areas of the effects are equal. If not, redistribute the available temperature difference and recalculate until they are equal or close enough.