Cutting Carbon-Source and Phosphorus-Chemical Costs at an AAO Plant: Eight Proven Measures

2026-11-13 13:07:14
立即下载

As provinces tighten their discharge standards to improve surface water quality, the limits on total nitrogen and total phosphorus keep falling. Beijing's Discharge Standard of Water Pollutants for Municipal Wastewater Treatment Plants (DB11/890-2012) cut total nitrogen for new plants in Class A from 15 mg/L to 10 mg/L and total phosphorus to 0.2 mg/L. Between 2015 and 2018 Tianjin, the Chaohu basin, Sichuan, Zhejiang and the Taihu basin each brought total nitrogen down to 10 mg/L and total phosphorus to 0.3 mg/L. Kunming's local standard is the strictest of all: Class A of its Discharge Limits of Major Water Pollutants for Municipal Wastewater Treatment Plants sets total nitrogen at 5 mg/L and total phosphorus at 0.05 mg/L, which the industry calls the double-five standard.

SINOKLE

Total nitrogen and total phosphorus limits in provincial and basin standards compared with Class IV of the national standard (mg/L).

Every tightening of the nitrogen and phosphorus limits pushes up spending on carbon source and on phosphorus-removal chemicals. That in turn forces plants to optimise the process, to compare and switch chemicals, and to modify the works, so as to keep those costs under control.

The AAO process is the most widely used municipal treatment train, which makes chemical cost reduction there the priority. Carbon-source consumption can be cut by optimising the return ratios, controlling the dissolved oxygen of the internal return liquor, feeding at several points, intermittent aeration, relocating the dosing point and comparing chemicals. Phosphorus-removal chemical consumption can be cut by controlling the sludge age, controlling the dissolved oxygen of the anaerobic tank, relocating the dosing point and comparing chemicals.

The case below is a plant in Beijing that runs AAO and discharges to Class A of DB11-890/2012. It shows what these measures achieved in practice.

SINOKLE

Process flow sheet of the plant: AAO plus a deoxygenation tank.

The Plant

The plant is designed for 6000 m³/d. The biological train is AAO followed by a deoxygenation tank, and the effluent meets Class A of DB11-890/2012. Actual flow is about 1700 to 2000 m³/d, so only half of the biological capacity is in service. The influent quality is given in the table below.

SINOKLE

Influent quality at the plant.

Where the Money Was Going

Carbon source was overdosed. A liquid carbon source with a COD equivalent of 80×104 mg/L was being dosed at about 170 mg/L, costing roughly 0.45 yuan per tonne of water.

Phosphorus chemical was overdosed. Ferrous chloride at 25 percent strength was being dosed into the anoxic tank at about 390 mg/L, costing about 0.16 yuan per tonne. The excess ferrous iron was oxidised in the ozone contact tank, which also hurt effluent suspended solids and colour. Iron carried into the biological tank suppressed biological phosphorus removal and depressed both biomass activity and nitrogen removal.

The return sludge tank was running too full. Its level was high enough for waste sludge to flow by gravity into the sludge storage tank. Whenever dewatering stopped, the surplus sludge left through the overflow pipe and returned to the lift pump station, with four consequences: the sludge absorbed and adsorbed COD from the influent, wasting carbon that the denitrification step needed; the iron-laden sludge corroded screens, pumps and other equipment; the water had to be pumped a second time, wasting power; and phosphorus already removed from the system came straight back into it.

The Eight Measures

1. Change the phosphorus chemical and its dosing point. Ferrous chloride was replaced with ferric chloride, and the dosing point moved from the anoxic tank to the secondary clarifier effluent channel. The initial dose was 90 mg/L, reduced in steps to 45 mg/L. Effluent colour and suspended solids improved as well.

2. Waste less sludge and raise the mixed liquor concentration. Sludge wasting was cut from 8 hours a day to 4 hours a day, and the mixed liquor suspended solids in the biological tank were raised stepwise from 4500 mg/L to 6000 mg/L.

3. Lower the external return ratio. The external return pump was brought down from 48 Hz to 37 Hz, taking the return ratio from 130 percent to 90 percent. A lower return ratio also thickens the waste sludge and improves dewatering.

4. Control dissolved oxygen in the aerobic tank. Dissolved oxygen at the end of the aerobic tank was brought down from 1.5 to 2.5 mg/L to 0.5 to 1.5 mg/L, and the ORP of the anoxic tank fell from about minus 50 mV to about minus 100 mV, which improved the environment for denitrification.

5. Move the carbon-source dosing point. Dosing was moved from the anaerobic tank to the inlet of the anoxic tank, and the dosing pipe outlet was moved from above the water surface to about 0.5 m below it. Liquid carbon source consumption fell from 170 mg/L to 125 mg/L.

6. Stop the sludge storage tank overflowing. The start level of the secondary clarifier scraper was lowered from 4.5 m to 3.5 m and its stop level from 5 m to 4 m, which lowered the return sludge tank level and stopped sludge flowing into the storage tank by gravity. Wasting from the high-efficiency clarifier was rescheduled to coincide with dewatering, and the wasting period was controlled, so the storage tank no longer overflowed.

7. Feed at two points. The inlet gate of the anoxic tank was opened so that flow splits between the anaerobic and anoxic tanks in a 2:1 ratio.

8. Dilute the PAC dose. Because the PAC flow was small, the dosing pump kept blocking, so the PAC was diluted by half before dosing. The PAC dose in the high-efficiency clarifier came down from 45 mg/L to about 25 mg/L.

What the Measures Saved

SINOKLE

Chemical cost before and after the optimisation.

With these measures in place, and with the water temperature falling from 19 to 14 degrees Celsius while the effluent stayed within standard, the carbon-source cost fell by 0.194 yuan per tonne and the phosphorus-chemical cost by 0.141 yuan per tonne. At 2000 m³/d that is around 245,000 yuan a year saved on chemicals.

Conclusions

Running experience shows that raising the sludge concentration within reason, optimising the return ratios, controlling dissolved oxygen at the end of the aerobic tank, relocating the dosing points and feeding at more than one point all bring the carbon-source cost down. Choosing the right phosphorus chemical, the right dosing point and a diluted dosing regime brings the iron salt and PAC costs down. Together these measures hold the effluent inside a strict discharge standard while cutting the plant's operating cost.