What Is a Stabilization Pond? Types and Design Parameters of Wastewater Treatment Lagoons

2026-11-18 13:09:49
立即下载

What Is a Stabilization Pond?

A stabilization pond (wastewater treatment lagoon) is an artificial ecosystem driven by solar energy. Aquatic plants are cultivated in the pond together with fish, ducks, geese and other aquatic farming, forming a multi-level food web. Under the initial energy input of sunlight, organic pollutants entering the pond are degraded and transformed through material migration and energy transfer along several food chains. As a result, pollutants are not only removed but also recovered as resources in the form of aquatic crops, fish and poultry, while the clarified effluent can be reused as reclaimed water. Wastewater treatment and resource recovery are therefore combined in a single system, turning treatment into resource utilization.

The artificial ecosystem builds several food chains by planting aquatic vegetation and farming fish, ducks and geese. It contains decomposers (bacteria and fungi), producers (algae and other aquatic plants) and consumers (fish, shrimp, shellfish, snails, ducks, geese and wild waterfowl). The three groups cooperate to treat and utilize the pollutants in the wastewater. When suitable quantitative and energy ratios are maintained between trophic levels, a well-balanced ecological system can be established. In such a pond, organic pollutants are first degraded by bacteria and fungi; the final inorganic products then serve as carbon, nitrogen and phosphorus sources which, with solar energy as the driving force, enter the metabolism of the food web and migrate step by step from lower to higher trophic levels, finally becoming aquatic crops, fish, shrimp, mussels, geese and ducks - a considerable economic return.

Key Advantages of Stabilization Ponds

  • Low construction cost. Ponds make full use of local terrain and require simple structures, so the investment is low.

  • Resource recovery. Treated effluent can be used for agricultural irrigation or for farming aquatic plants and fish; with the income from comprehensive utilization, operation can reach break-even or even generate a surplus.

  • Energy saving. With proper design, wind can provide natural aeration and re-oxygenation, reducing power consumption. No complex mechanical equipment is needed, operation is stable, and the running cost is only 1/5 to 1/3 of that of a conventional wastewater treatment plant.

  • Minimal sludge production. Sludge output is only about 1/10 of that of the activated sludge process. Sludge from the upstream units can be sent to lotus or reed ponds or nearby farmland as organic fertilizer. In pond systems with an anaerobic pond upstream, the sludge fermentation pit at the bottom performs acidification, hydrolysis and methane fermentation, converting organic solids into liquid or gas and achieving near-zero sludge discharge.

  • Adaptable to low concentrations. In many Chinese cities the wastewater BOD is below 100 mg/L, too low for activated sludge processes and especially oxidation ditches to run properly, while stabilization ponds can treat both high-strength organic wastewater and low-concentration sewage.

Main Types of Ponds

Aquatic plant ponds

Vascular aquatic plants such as reeds, alligator weed, water lettuce and water hyacinth are planted in the pond. They remove pollutants from the water effectively, with particularly good performance for nitrogen and phosphorus.

Anaerobic ponds

The anaerobic pond works like other anaerobic biological processes: organic substrates are degraded by anaerobic bacteria in two stages. First, acid-producing bacteria hydrolyze complex macromolecular organics into simple organics (organic acids, alcohols, aldehydes); then methanogenic bacteria ferment these substances into methane and carbon dioxide.

Anaerobic ponds perform well for high-temperature, high-strength organic wastewater from food processing, biopharmaceuticals, petrochemicals, slaughterhouses, livestock farms, pulp and paper, brewing, pesticides and similar industries. They also remove part of the alcohols, aldehydes, phenols, ketones and heavy metals.

Influent requirements: the organic load must not be excessive - organic acid concentration in the system should be below 3,000 mg/L; influent sulfate should not exceed 500 mg/L; the BOD:N:P ratio should be about 100:2.5:1 and C:N about 20:1; pH should be kept between 6.5 and 7.5; toxic substances must be absent, and heavy metal concentrations must comply with the Code for Design of Outdoor Wastewater Engineering.

A minimum permissible BOD surface loading must be specified. In China the minimum permissible loading of anaerobic ponds is 300 kg BOD5/(104 m2·d) in the north and 800 kg BOD5/(104 m2·d) in the south. Design in most countries is based on volumetric loading: for municipal wastewater, design data from seven US states show BOD volumetric loads of 0.2-0.4 kg BOD5/(m3·d), although Montana uses a much wider range of 0.032-1.6 kg BOD5/(m3·d). Loads for industrial wastewater should be confirmed by pilot tests, such as the Chinese pilot data for meat-processing wastewater treated in anaerobic ponds.

When the wastewater carries a high VSS content, the design should use the VSS volumetric loading instead. Typical geometric parameters: effective water depth h1 = 3.0-5.0 m (excessive depth lowers the bottom temperature and is unfavorable); sludge storage depth h2 ≥ 0.5 m, with municipal sludge estimated at 50 L per person per year and a desludging interval of 5-10 years. The inlet is located near the bottom, 0.6-1.0 m above the pond floor so that the influent mixes with the settled sludge; the inlet pipe is normally 200-300 mm in diameter (not less than 300 mm for oily wastewater). The outlet is submerged below the water surface by at least 0.6 m and must be beneath the scum or ice layer. At least two inlets and two outlets are generally required, though a single inlet is acceptable when the pond bottom is narrower than 9 m. Because the anaerobic pond sits at the head of the system and accumulates most of the sludge, at least two ponds should be built in parallel for alternate desludging, and a single pond should not exceed (0.8-4) × 104 m2. Anaerobic ponds are usually placed first as pretreatment, followed by facultative ponds, aerobic ponds or polishing ponds, which greatly reduces the volume of the downstream units.

Facultative ponds

The facultative pond is the most widely used stabilization pond, with an effective depth of 1.0-2.0 m and three vertical zones: an aerobic surface layer, a facultative middle layer (transition zone) and an anaerobic bottom layer where settled sludge is digested anaerobically. In the aerobic zone, algae produce oxygen through photosynthesis and organics are oxidized by aerobic heterotrophic bacteria. In the facultative zone, dissolved oxygen is scarce and intermittent; facultative heterotrophic bacteria oxidize organics with the little oxygen available and, when molecular oxygen is absent, use NO3- and CO32- as electron acceptors for anaerobic metabolism.

If a facultative pond serves as the first stage, pretreatment is required with the same rules as for anaerobic ponds, except that the influent BOD:N:P ratio should be 100:5:1. Design normally uses the empirical BOD surface loading method, which correlates strongly with the average winter air temperature; the main design parameters recommended for municipal facultative ponds were established by China's national key scientific research program. A system usually contains at least three facultative ponds, mostly in series, with the first pond occupying about 30%-60% of the total area; a single pond is generally between (0.8-4) × 104 m2.

Aerobic ponds

An aerobic pond is a shallow (0.3-0.5 m) pond in which bacteria and algae live in symbiosis. Sunlight penetrates to the bottom; bacteria, protozoa and algae coexist, and the dissolved oxygen needed by aerobic microorganisms is supplied by algal photosynthesis and wind mixing. Degradation is essentially the conversion of dissolved organic pollutants into inorganic matter and solid biomass - bacterial and algal cells. Aerobic bacteria oxidize organics into CO2, NH4+ and PO43- and synthesize new cells, while algae use the CO2, inorganic nutrients and water to build new algal cells with light energy and release oxygen, which in turn sustains bacterial metabolism. Zooplankton feed on bacteria, algae and detritus as primary consumers. Producers, decomposers and consumers together with the pond water form a complete aquatic ecosystem that circulates matter and energy and purifies the incoming wastewater.

Algal photosynthesis makes dissolved oxygen and pH fluctuate day and night. During daylight, oxygen released by photosynthesis exceeds bacterial demand and DO may reach saturation; at night photosynthesis stops while respiration continues, so DO falls to its minimum before dawn and rises again after sunrise. The pH follows the CO2 balance of the carbonate system: photosynthesis lowers CO2 and raises pH during the day, while nighttime CO2 accumulation lowers it.

Aerobic ponds are suitable for nutrient removal and for treating dissolved organics; because of their good performance they are mostly used in series behind other ponds for further treatment, such as polishing secondary effluent.

Aerated ponds

Aerated ponds are deeper than 2 m and are supplied with oxygen by mechanical aeration so that the whole water body stays aerobic. They fall into two categories - fully aerobic and facultative aerated ponds. Instead of relying mainly on natural purification, oxygen is supplied artificially, usually by aerators mounted on the pond surface; the process sits between extended aeration of the activated sludge process and conventional lagoons. Design also uses the BOD5 surface loading method, typically 1-30 kg BOD5/(104 m2·d). The aeration equipment is the same as in other aerobic processes: fine-bubble diffused aeration, surface aerators and horizontal-axis brush aerators widely used in activated sludge plants and oxidation ditches can all be applied.

Applications in China

Because stabilization ponds are economical, energy-saving and capable of wastewater resource recovery, they have received strong support from the Chinese government since research began in the 1950s. The former National Environmental Protection Agency funded 3 million yuan for the reconstruction and expansion of the Qiqihar pond system. By 1990, 118 stabilization ponds had been built in China with a total treatment capacity of 1.9 million tons per day.

Beyond domestic sewage in small and medium-sized towns, stabilization ponds are widely used for industrial wastewater in agriculture, animal husbandry and aquaculture. In western China, where land is abundant and population sparse, lagoon technology has particularly broad prospects.

  • Suihua oxidation pond. Covering 130,000 m2 with a volume of 380,000 m3, two lift stations, four auxiliary pumping stations and 19,500 m of brick-lined seepage-control channels, it irrigates 6,000 mu (about 400 ha) of farmland. The purified water meets the irrigation water quality standard; after seventeen years of irrigation there has been no pollution of soil, vegetables or groundwater. The effluent carries 22.5 mg/L nitrogen, 2.93 mg/L phosphorus and 6.0 mg/L potassium, saving about 31,430 kg of chemical fertilizer and 1 million tons of groundwater annually. Vegetables irrigated with the pond effluent yield 25,000-40,000 kg more per year on average, ripen 7-10 days earlier and add 250,000-300,000 yuan of annual income.

  • Changcun coal mine oxidation pond (Yima Coal Group). To stop mine water polluting the Jian River, the mine converted an abandoned pit into a 150,000 m3 pond treating 82,000 m3 of mine water per month at an investment of more than 400,000 yuan. The treated water serves as industrial water both above and below ground, and fish farming in the pond yields more than 20,000 kg per year; the pond area is now a well-known scenic spot.

  • Gaotang Paper Group oxidation pond. A 12 million yuan second-phase project covering more than 600 mu operates around the clock. The treated papermaking wastewater can be used for aquaculture and irrigation, and about 80% of the water is recycled back into production, making the plant effectively zero-discharge.

  • Dongying eco-engineering project. Completed in October 2000 with a design capacity of 100,000 t/d, an area of about 110 hectares and a total investment of 67 million yuan, it is one of the most complete stabilization-pond treatment plants at home and abroad. An existing reservoir was divided into high-rate anaerobic, aerated and aerated fish ponds, while nearby saline wasteland was converted into fish, lotus and reed ponds for ecological utilization. During commissioning - before fish fry were stocked and lotus or reeds planted - the final effluent already met China's Integrated Wastewater Discharge Standard (GB 8978-1996) class II. The design emphasized harmony with the surroundings: embankments were neatly built and revetted with rubble stone, and the aerated fish pond doubles as a landscape feature, turning the plant into an ecological park. Compared with conventional activated sludge, the project has lower capital investment, lower operating cost and easier maintenance.

Mobile phone/Whatsapp

+86 18926412206

Email

marketing@sinokle.com

Address

Room 2301, Building 1B, Smart Home, Baolong Street, Longgang District, Shenzhen, China

Phone