Storm Inflows and Combined Sewer Shock: Wet-Season Process Adjustments at Municipal WWTPs

2026-11-16 13:07:25
立即下载

Heavy rainstorms now occur frequently across the country, and they have a major effect on the biological stage of both municipal wastewater treatment systems and in-plant industrial treatment systems. Cities are generally built with separate storm and sanitary sewers, so in theory the stormwater pipework and the sewage pipework do not interfere with each other. In practice, however, storm sewers are often designed with an underestimated peak intensity for short-duration cloudbursts, and with increasingly variable weather the result is a real risk of urban waterlogging. In addition, because chemical agents such as flocculants may be used on site, treatment plants commonly route rainwater collected inside the plant boundary into the wastewater treatment system. This immediately causes a large increase in influent volume. The massive influx of stormwater also sharply lowers the organic load concentration of the influent, which in turn reduces the sludge concentration and can cause sludge to rise to the surface.

Two recommendations for operating the wastewater treatment system:

(for periods of intense rainfall)

  1. When a rainstorm arrives, the influent to the treatment system can be shut off quickly to prevent the shock that stormwater imposes on the system. During a short period of intense rainfall (0–5 h), the return system (if present) can be shut down and the blowers of the aerobic system can be stopped.

  2. In the case of prolonged heavy rainfall and flooding, it is recommended that the aerobic and anoxic tanks be emptied, and that the biological system simply be re-cultured once conditions return to normal. For anaerobic towers, it is advisable to close the inlet and outlet and keep the heating system off, so that the plant can be brought back into service quickly after the event.

Wet-Season Operating Recommendations for Wastewater Treatment Plants

Once summer arrives the rainy season begins. Rainfall increases in most regions and many areas experience substantial precipitation events. During these events, stormwater in small and medium-sized towns across the country — and in the old urban districts of some large cities — is still carried mainly by combined sewer systems. In other words, this stormwater enters the municipal sewer network, and the design peculiarities of combined systems create serious problems for the terminal point of the chain: the wastewater treatment plant.

1. How stormwater affects municipal plants under combined sewer systems

(1) Dilution of the influent concentration. Plants in small and medium-sized towns in northern China are generally designed at a modest scale, most of them around 10,000 m³/d, with an hourly inflow of roughly 400–500 m³/h, and they typically serve an area of about 10–15 km². The climate of northern towns concentrates the whole year's rainfall in July to September, and those three months account for more than half of the annual total. Taking an annual average precipitation of 450 mm for the North China region (the calculation below refers mainly to small and medium-sized towns there), wet-season rainfall is about 250 mm and the average monthly rainfall about 80 mm. For a small town with a 10 km² catchment area, the stormwater converging on the treatment plant in a single wet-season month can be calculated as follows.

The volume of stormwater flowing to such a plant in one wet-season month reaches 800,000 m³. After deducting infiltration, the water taken up by vegetation, and the portion that flows directly into nearby rivers, roughly 50% of that rainwater — some 400,000 m³ — enters the plant during that month and is treated together with the domestic sewage.

A small town with a treatment capacity of 10,000 m³/d that receives an additional 400,000 m³ of stormwater would face an average daily throughput of 23,000 m³. Because the plant itself carries a design margin of 20–30%, about 13,000 m³/d actually enters the plant, and the remainder overflows out of the plant through the overflow pipe. Where no overflow pipe exists, this water is stored in the municipal network until the plant has digested all of the retained volume.

The analysis above shows that during the wet season the inflow to plants in small northern towns increases by a factor of 1–1.3. Consequently, the influent concentration at plants that run at full load in the dry season is diluted by a factor of 1–1.3, and sometimes by as much as 2–3. Under this dilution, influent COD, BOD, ammonia nitrogen and total phosphorus all fall to about one-half to one-third of their normal values.

Rainfall events fall into two types: short, intense downpours and long, light rain. Because the municipal network itself has a certain storage capacity, a short downpour will continue to exert a strong diluting effect on the influent for some time afterwards, while long, light rain affects and dilutes the influent quality over a very extended period.

(2) Higher sand and silt content in the influent. Northern cities generally have limited vegetation cover, a large proportion of exposed ground and a good deal of wind-blown dust. During the wet season, rainwater scours road dust and the silt of exposed surfaces very effectively. With rainwater and sewage superimposed on each other, the volume in the network grows and the flow velocity rises, so most of the sand, silt and gravel is carried into the plant.

Some towns have extensive intercepting trunk sewers, usually laid in river channels where this is convenient. During the wet season, when rivers discharge floodwater, large volumes of mountain flood surge into the network. This greatly raises the content of inorganic grit and sand in the wastewater and imposes a heavy inorganic load on the plant.

(3) Higher hydraulic load on the plant. Small and medium-sized plants rarely run at full capacity in normal operation; most run at a load ratio of 70–80%. During the wet season, large volumes of stormwater enter the plant's collection well and reach the overflow pipe connection. The water level in the plant then exceeds the design influent volume, the net head of the pumps falls and their flow rises, so the lifted volume exceeds the normal daily figure. Many plants also take on part of the city's flood-discharge duty and must open their flood gates during the wet season, so the actual volume of mixed stormwater and sewage entering the plant far exceeds the normal inflow.

With these large wet-season inflows, the actual retention time in each treatment unit is shortened and the hydraulic load on the treatment facilities rises to the limit of the design margin: the plant operates in an overloaded condition.

(4) Changes in influent quality. Relevant studies show that pollutants in road stormwater runoff come mainly from tyre wear, the use of antifreeze, vehicle leaks, the use of pesticides and fertilisers, and discarded waste. The polluting constituents include organic and inorganic compounds, nitrogen, phosphorus, metals and oils. Because large volumes of stormwater mix into the sewage, the original quality structure of the wastewater is strongly affected. The acidic character of urban stormwater changes the pH of the influent. Because stormwater and water from some river channels flow in, a large amount of atmospheric oxygen is carried into the wastewater, raising its DO value. Nitrogen and ammonia nitrogen in the air dissolve into the rainwater during rainfall, raising total nitrogen and ammonia nitrogen in the water. Heavy metals deposited on road surfaces by tyre wear are also washed into the plant, causing heavy metal exceedances in the influent.

2. The harm that rainstorms do to a treatment plant

(1) Excess grit and suspended solids put heavy pressure on pretreatment. Stormwater gullies and inlets along roads in northern regions are swept with litter by cleaning staff or used for dumping wastewater all year round. When rivers discharge floodwater, intercepting pipes laid in the river channel admit large quantities of branches, stones and silt into the sewer network. Within a short time the stormwater carries this debris into the plant, placing great pressure on the pretreatment stage.

During the wet season, the impact of large volumes of wastewater carrying large amounts of debris causes serious damage to the rake teeth and bars of the coarse and fine screens in pretreatment. Large floatables jam the lower drive wheels of the screens, so the screen drive jumps out of position and stops working. Some heavier floatables break rake teeth and bars. A sudden surge of scum also puts operating pressure on the screenings handling and conveying equipment downstream of the screens: screenings accumulate faster than the screw conveyor can deliver them to the disposal point, so they pile up and may even damage the screens. Some large branches break pump impellers. Large volumes of river sand fill or block the grit removal facilities. If the pretreatment units are bypassed, the debris in the stormwater passes into the downstream treatment units, silting up the aeration tank and blocking the control valves of the secondary clarifier siphon pipes.

(2) Influent concentration too low for the biomass to sustain itself. Under the diluting effect of stormwater, the organic concentration of the influent falls to one-half to one-third of its dry-season value. The nutrient carbon source available to the biomass in the plant drops abruptly, so the activated sludge ages and its overall structure changes markedly. At the original sludge concentration the biomass is no longer assured of substrate and begins to die off, and the sludge concentration trends downwards. When the wet season is abundant, the plant may be diluted by stormwater for one to two months at a time, and the activated sludge system then operates at low concentration for a long period and cannot maintain its original concentration. Small and medium-sized plants in particular seldom provide variable-frequency control on their blowers and cannot modulate the aeration rate. With low influent concentration and low sludge concentration but aeration maintained at a high level, the ageing of the whole activated sludge system accelerates, and in severe cases the entire system collapses.

Because of dilution, the colloidal matter in the domestic sewage is diluted as well, and the colloids that build the activated sludge flocs are reduced, so deflocculation becomes severe. After a period of stormwater shock, the flocs become smaller, breaking down from visible granular flocs into fine fragments and eventually dispersing completely. The foam on the aeration tank changes from the original earthy-brown biological foam into the white chemical foam typical of the start-up period. The activated sludge system then loses its biological treatment capability altogether.

(3) Hydraulic load too high, a severe shock to the activated sludge system. During the wet season the volume lifted by the plant suddenly increases, raising the flow velocity through every pretreatment unit — especially the through-screen velocity of the screens. At a high through-screen velocity, part of the screenings cannot be intercepted by the screens and passes into the downstream units, blocking downstream equipment.

In the biological stage, a high hydraulic load accelerates the flow of wastewater through the reaction tanks and shortens the contact and reaction time between wastewater and biomass, so the degree of treatment falls and performance deteriorates. Because the velocity increases, the activated sludge flocs suffer severe impact damage; large flocs disintegrate under the impact of the high flow, and prolonged operation leaves the flocs broken up.

In the secondary clarifier the inflow load rises and the settling time is shortened. Dispersed activated sludge has poorer settling characteristics and settles more slowly, yet the volume of water is greater and the turbulence stronger, so the sludge cannot settle effectively in the clarifier. It is carried out with the supernatant into the downstream treatment stages, which further reduces the activated sludge concentration in the biological tank.

Large quantities of activated sludge and fine river sand pass into the advanced treatment stage, increasing chemical consumption there, while the filters face a simultaneous increase in solids load and hydraulic load and must be backwashed frequently, which is extremely damaging to the equipment.

During the wet season, plants equipped with primary clarifiers accumulate large amounts of sand and silt in them, greatly increasing the operating pressure on the dewatering machines. The sand also wears the sludge lifting and dewatering equipment. At the same time, the influx of sand changes the nature of the sludge, so the existing dewatering chemicals must be adjusted accordingly to meet the dewatering requirements of a sludge dominated by inorganic matter — which raises operating costs.

(4) High ammonia nitrogen, low pH and high DO alter the habitat of the biomass. Because first-flush stormwater scours the urban environment, the organic pollutants it contains differ in composition and proportion from those of everyday domestic sewage. The habitat of the activated sludge changes and the structure of the microbial community shifts. Under a short shock the change is not large, but under a prolonged shock many organisms appear in states different from normal, and unusual organisms can appear that indicate a change in water quality and in the microbial system — some plants, for example, have observed three-toed rotifers appearing after prolonged stormwater entry.

(5) Effluent quality exceeds the standard. A shocked activated sludge system, secondary clarifiers under high hydraulic load and the advanced treatment stage all mean that the effluent quality may exceed the standard. In particular, if the influent is diluted to a very low level over a long period, the activated sludge system collapses and the effluent ultimately exceeds the standard. During rainstorms, SS in the effluent very easily exceeds the limit. Under prolonged dilution, the organic concentration of the influent is diluted so low that the carbon source is insufficient, and exceedances in the early stage are mainly of nutrient elements such as ammonia nitrogen and TP; later, as the whole activated sludge system collapses, every parameter exceeds the limit.

3. Process adjustment measures at a plant during a rainstorm

Overall, the rainy season in the north is concentrated within two to three months, and the various situations that arise, together with their after-effects, are essentially eliminated within three to four months, after which operation returns to normal. During those four months a series of process adjustments must be made at the plant, and once the stormwater has completely receded the process must be returned to normal operation.

(1) Adjust in advance. During the wet season the influent concentration falls, organic carbon source is reduced and the biomass lacks substrate, so the organisms pass through a phase of starvation and self-digestion. Before the rainy season arrives, therefore, the sludge concentration can be reduced appropriately so that the activated sludge system receives a smaller shock when influent quality suddenly falls, and the process as a whole can ride smoothly through the period of water-quality fluctuation.

(2) Control the influent volume. During the wet season, the lifted volume should be controlled by switching between sewage lifting pumps or by throttling the discharge valve of the lifting pump, so that the wet-season inflow matches the normal lifted volume, with the surplus discharged through the overflow line. Controlling the volume in this way keeps the downstream units operating under a stable hydraulic load. Note that during the wet season the level in the collection well rises and the lifting capacity of the pumps increases: even without changing pumps, the actual lifting capacity is greater than the normal daily figure, so control must be based accurately on the influent and effluent flow meters to keep the lifted volume level with the normal volume.

(3) Change the process route. Because the influent is diluted by stormwater and its concentration falls, the pollutant equivalent is reduced while the influent volume is held at a normal level, so the organic load on the biological stage drops. Plants with primary clarifiers can adopt an operating route that bypasses the primary clarifier, reducing the removal of organic matter by sedimentation in pretreatment and preserving the organic carbon source for the biological stage so that the growth requirements of the biomass are met.

Where long-term low influent persists under the influence of the wet season, and the biological stage has two parallel treatment trains, the influent volume and return sludge of one train can be shut off or throttled so that all, or more than three-quarters, of the flow and return sludge enter a single biological train. This gives priority to maintaining the treatment performance, sludge concentration and biomass of one train, while the other train serves as a tank through which water simply passes. Once the stormwater in the influent has receded, the fully fed train can then act as the main body for restoring the biological system, which makes commissioning and recovery much faster.

(4) Reduce the dissolved oxygen in the aeration tank. With low-concentration influent and low-concentration activated sludge after natural digestion, the aeration rate in the biological stage must be adjusted accordingly and reduced. The aeration rate is cut by reducing the number of blowers in service, by variable-frequency control or by intermittent aeration, so as to keep the DO in the effluent of the biological stage at about 2 mg/L and prevent the low-concentration activated sludge from accelerated ageing caused by over-aeration, which would lead to sludge disintegration or collapse.

(5) Adjust the returns. During the wet season the influent quality changes and the organic concentration falls, so the external return rate should be lowered appropriately to slow the ageing of activated sludge returning to the aeration tank. If an internal return system is provided, its rate should be lowered as well, because stormwater carries a high DO: the wastewater entering the anaerobic and anoxic zones contains more oxygen than in normal operation, and with less carbon source available, denitrification consumes a large part of the carbon, leaving the aerobic zone with insufficient carbon to sustain the growth and survival of aerobic organisms. The result is a drop in sludge concentration or even a collapse of the system.

(6) Supplement nutrients. When the wet season brings the influent concentration below one-third of its original value and this persists for more than two weeks, dosing a carbon source should be considered in order to supplement the nutrient demand of the activated sludge system. Where economic conditions permit, the usual options are glucose, methanol, ethanol or flour; where budgets are tighter, concentrated septage liquor drawn from municipal septic tanks can be considered as a source of the carbon required. However, municipal plants are large in scale, so the volume of carbon source needed and the cost are both high, and relying on nutrient supplementation over the long term places pressure on operation.

(7) Re-culture and restore operation. In recent years, under the influence of changing climatic conditions, annual rainfall in northern regions has increased and wet-season rainfall has risen, so combined storm and sanitary sewer systems impose an even greater shock on plant operation. It may happen that, even after the series of adjustments described above, the activated sludge system still cannot be kept stable through the flood season and eventually collapses, with effluent exceeding the standard. In that case the activated sludge is re-cultured after the rainy season has ended and the stormwater has completely drained from the network.

(8) Report to the competent authority. The impacts and shocks that the wet season imposes on a plant served by a combined sewer network, together with the data on changes in influent and effluent, should be documented: photograph the influent quality conditions, compile the results into a report, and report to the higher competent authority in good time. Actively coordinate with the housing and urban-rural development department in inspecting leakage points in the network, cooperate fully with on-site inspections by the environmental supervision department, explain the situation clearly, and maintain normal, stable operation for as long as the combined sewer system cannot be corrected in the short term.

Every summer brings the traditional rainy season, and wastewater treatment plants everywhere are strongly affected by combined sewer systems during wet-season operation. In the short term, the combined-sewer situation in many cities will persist, so operators and managers must learn how to respond to the shock of stormwater and how to adjust the process accordingly.

Mobile phone/Whatsapp

+86 18926412206

Email

marketing@sinokle.com

Address

Room 2301, Building 1B, Smart Home, Baolong Street, Longgang District, Shenzhen, China

Phone
E-mail
Map
QQ Service