Wastewater Plant Troubleshooting in the Field: 21 Real Operating Questions and Answers

2026-11-16 13:05:48
立即下载

The questions and answers below come from day-to-day operating discussions at wastewater treatment plants. They cover the situations operators actually run into — falling pH, sludge washout, nitrification failure, foaming, floating sludge, filamentous bulking — and how experienced operators diagnose and correct them. Question 1 through Question 21 are abridged for clarity; concentrations are in mg/L unless noted.

Q1. pH keeps falling in a printing-and-dyeing pretreatment plant under retrofit

Question: The plant treats 300 t/d of printing-and-dyeing wastewater in pretreatment and is being retrofitted. The aerobic train is three tanks of 3×8×4 m; the anaerobic tank's mixers are not yet installed, so influent goes straight to the aerobic tanks, with return currently to the front end. Inflow is about 50 t/d, rising to full load once the anaerobic equipment is in. How can the falling pH be countered effectively?

Answer: (1) Switch off aeration in the front part of the aerobic train and run that part as an anaerobic tank — at the current flow the tanks give nearly two days of retention, which can be put to use. (2) If the pH measurement is confirmed, dose alkali immediately — not only at the inlet and the equalization tank, but at primary settling, aeration and secondary settling as well; then find the cause and analyse the problem.

Q2. Coking plant: sludge loss and rising COD after a load shock

Question: A coking plant treats wastewater through oil separation → equalization → first aeration → primary clarifier → anoxic tank → aerobic tank → secondary clarifier → coagulation → advanced treatment. Primary-clarifier sludge returns to the first aeration stage, secondary-clarifier sludge to the anoxic tank, and nitrified mixed liquor to the anoxic tank; no tanks carry media. Total HRT exceeds 88 h. Inflow is 50 m³/h with COD 4500–5000 and ammonia nitrogen 80–120. The equalization tank used to hold COD around 2000, primary-clarifier effluent around 900–1200; SV30 in the first aeration stage was about 20 percent and DO about 1; secondary-clarifier effluent COD was about 300. Recently the equalization COD rose to 2600–2900 for about seven days, primary-clarifier effluent turned very turbid and rose to around 1300, secondary-clarifier effluent COD reached 600, and the anoxic and aerobic tanks lost sludge heavily — mixed-liquor concentration fell from 10–15 percent to under 5 percent (SV30), while aerobic DO shot up to 7–8. The equalization COD is back to about 1300; iron salt is being dosed in the aerobic tank to hold on to the sludge, phosphate dosing has been increased, and glucose is being added to rebuild sludge concentration. Any advice?

Answer: (1) After the load rose, sludge washed out because settling failed, so the fall in sludge concentration is natural. The priority is to stabilize the system and restore settling: reduce the aeration rate — this helps settling and helps new sludge form, while over-aeration only accelerates sludge disintegration. (2) Dose flocculant sparingly — never to excess — and dosing should be sustained rather than one-off. (3) Adding phosphate will not do much for sludge formation if phosphorus is not actually deficient; if it is deficient, supplement promptly. (4) If sludge wasting can be controlled, cut the wasting rate as far as possible until sludge concentration recovers, then return to the normal value. (5) The secondary-clarifier return currently goes to the anoxic tank, not the aerobic tank, which works against rebuilding sludge concentration; consider rerouting it to the aerobic tank until the system recovers, then change it back.

Q3. Hydrolysis-acidification sludge carried into the aerobic tank

Question: The hydrolysis-acidification tank is stirred to keep sludge suspended, but that sludge flows into the aerobic tank — will it shock the aerobic tank? The aerobic sludge has turned black and DO is only about 0.5, and aeration cannot be lowered any further without losing the tank. Equalization influent COD is about 3000, but hydrolysis-tank effluent has reached 3500, with floating scum on top. How to solve this?

Answer: (1) A small carryover is not a problem as long as the aerobic system keeps wasting sludge normally; if the carryover is large, some of it leaves with the effluent and affects SS and COD — weigh this against the discharge targets and tolerate it if you can. (2) Lowering DO refers to the equalization tank: if dissolved oxygen there is high, it harms the hydrolysis-acidification process, which needs an anoxic state. The low DO in your aerobic tank can be raised by more aeration — there is no contradiction between the two.

Q4. F/M running at 0.5 and above in an A/O system

Question: Our plant runs anaerobic + aerobic. F/M should normally sit between 0.2 and 0.4, but actual operation reaches 0.5 or higher, while all other indicators are normal. Why?

Answer: With a high organic load, the effluent value rises correspondingly. From the formula: at a given influent organic concentration, a lower sludge concentration raises F/M. There is also the extreme case where the influent organic concentration is so high that the sludge cannot grow in proportion, being limited by dissolved oxygen and tank volume, which also pushes F/M up.

Q5. Poor nitrification in the aerobic stages of an A2/O system

Question: We run an A2/O process, but nitrification in the aerobic tanks is poor: influent and effluent ammonia have barely changed for about ten days and the system has not recovered. Industrial wastewater must be treated continuously, so stopping the feed is impossible. I tried increasing aeration: the first aerobic stage needs little oxygen and reaches 4–5 easily, so we hold DO at 3.0 there; the second aerobic stage sits at 1.0 — and it seems to need more oxygen than the first, for some reason. What else should I adjust?

Answer: (1) The DO difference between the two aerobic stages has two basic causes: (a) the aeration supplied per unit volume differs between the stages; (b) if the first-stage volume is small, microorganisms there mostly adsorb organics and decomposition happens mainly in the second stage — so the oxygen demand, and the DO drop, appear in the second stage. (2) Nitrification depends on: (a) pH — confirm it is not below 7; (b) sludge load — confirm the system runs at low load long-term, since nitrification efficiency falls at high load; (c) dissolved oxygen — from your description, unlikely to be the issue.

Q6. Flocs in one secondary clarifier's effluent, and how far to push internal return

Question: Two questions. (1) We run A2/O at about 6000 MLSS. One secondary clarifier's effluent carries flocs unevenly — some parts of the weir run clear, others visibly cloudy — while the other clarifier does not. We checked the weir's levelness; the maximum deviation is within ±8 mm. What is the cause? (2) How should the internal return be set? The design maximum internal return ratio is 200 percent, but an extra pump was installed, so up to about 300 percent is available. We run one, two or all three pumps for periods at a time and see no obvious difference in effluent. The basin HRT is unchanged whatever the internal return — does a larger internal return help TN removal, and can we simply run all three pumps at 300 percent? What are the drawbacks of a large internal return?

Answer: (1) If both clarifiers receive identical influent but only one settles poorly, the problem is in that clarifier. You checked the weir, but also look at: (a) the shroud around the central effluent outlet; (b) whether the sludge scraper fails to clean some zone, letting sludge linger there, break up and float out; (c) adjust the weir level anyway — do not dismiss an 8 mm deviation; with many small outlet notches along the weir, uneven level means uneven flow distribution along the water's path. (2) A larger internal return certainly helps denitrification, but pushed too far it has drawbacks: (a) it carries too much oxygen back into the anoxic zone; (b) it wastes energy.

Q7. Extending hydrolysis-tank sludge wasting to raise COD to the A2/O

Question: We run an inverted A2/O with a hydrolysis tank ahead of it; the hydrolysis tank is normally wasted one hour a day. Influent COD has been low recently — would extending the hydrolysis tank's wasting time raise the COD entering the A2/O train?

Answer: It can be understood this way: with less hydrolysis biomass, the wastewater entering the hydrolysis tank degrades less, and the pollutant concentration reaching the downstream system rises. But the change in wasting intensity is small, so the effect will be limited. That said, more wasting does improve the removal of inert inorganic matter in the hydrolysis tank, which helps hydrolysis performance to a degree.

Q8. Sudden drop in ammonia removal after rain in an SBR plant

Question: Our plant runs SBR with influent COD 200 and ammonia 20, sludge concentration steady around 6000, DO about 2 during aeration, and effluent ammonia steady around 1. It rained recently and ammonia removal suddenly fell: with influent still 20, effluent sometimes 8 and often around 10. Some say the load is too low and the sludge aged; I don't think aging could act this fast. Others say the rain washed in inert matter, but the sludge still looks healthy. What caused the sudden drop?

Answer: Cutting ammonia from 20 to 1 is removal above 99 percent, which is largely thanks to your sludge concentration of 6000 — but that brings a downside: the system's resilience to external fluctuation worsens. On rainy days a municipal plant typically sees inflow increase; with the total organic load unchanged but the flow sharply up, the system's adaptability suffers and removal fluctuates. Give it some time and the system should return to its previous state.

Q9. Sludge concentration falling day by day with no wasting

Question: Our plant has had very dilute influent recently — lots of rain — and effluent is stable with excellent, clear sludge separation. But in the last two days sludge concentration has fallen steadily: from 2000 to about 1700 yesterday, about 1500 today, and around 1300 tonight. The effluent keeps getting clearer, no sludge has ever been wasted, and nutrient (flour) dosing continues. Why does the concentration keep dropping?

Answer: Settle these points first: (1) whether a mixer or aerator has failed locally, letting sludge settle somewhere in the system; (2) whether the measurement data are biased; (3) whether the dilute influent itself is passively reducing the sludge; (4) whether, even without active wasting, some valve is not closing tight or sludge is leaking out somewhere; (5) whether high inflow is washing a large amount of sludge out of the system in bursts because settling fails.

Q10. Pale sludge, whole-layer rise and filamentous bulking in an A2/O plant

Question: Our A2/O plant has a primary clarifier ahead of the biological stage that runs irregularly — wasting is not continuous — but the effluent is normal with few impurities. Will this affect the biological stage downstream? Also, over many days of observation the sludge in the aerobic zone looks pale, close to grayish brown. Is this filamentous organisms or something else, and can it be improved? And because of filamentous bulking, the secondary clarifier sometimes shows the whole sludge layer rising, though it has not yet washed out with the water. The rising sludge is deep brown — is that normal?

Answer: (1) If the primary clarifier's effluent is normal, intermittent wasting does not affect the biological system downstream. (2) Pale color with a high settling ratio does indicate filamentous organisms; to improve it, increase the internal return and lengthen the bulking sludge's residence in the anoxic zone. (3) A whole sludge layer rising is mostly a filament problem (with effluent quality still good); it is not serious as long as the bulking does not worsen — but flow fluctuations can push the effluent over the limit.

Q11. pH falls fast during aerobic sludge cultivation

Question: During cultivation in the aerobic tank, pH falls quickly. Microscopy shows only a few Vorticella and Epistylis, but SV30 is increasing. How do we get the sludge cultivated faster?

Answer: (1) Check whether the influent itself is lowering the pH. (2) The observations show the cultivation is progressing well. (3) They also show the sludge is highly active. (4) Raising the influent substrate concentration appropriately will help the cultivation; and control aeration — if DO is not below 2 mg/L, reduce the aeration rate.

Q12. Dead sludge on the clarifier surface that thins out after a week

Question: There is a lot of dead sludge on the clarifier surface, which thins out after about a week. What is the cause?

Answer: For a settling basin the usual causes are: (1) denitrification lifting the sludge (the aeration tank surface would then be free of scum); (2) filamentous bulking raising the sludge's viscosity, so it floats with entrained gas after entering the clarifier (the aeration tank would show the same surface scum); (3) sludge poisoning lifting the sludge (usually with turbid effluent); (4) excessively large pH swings lifting the sludge.

Q13. Fine, fragmented sludge in a CASS basin

Question: The sludge in our CASS basin is fine and fragmented. Is this related to poor biodegradability of the wastewater from the acidification/equalization tank upstream? What other causes are there?

Answer: Look at the load entering the CASS basin. If the load is high, the upstream acidification/equalization stage needs to raise removal and hydrolysis performance. If the load is not high, consider whether the sludge has aged — an over-high sludge concentration in the CASS basin ages the sludge and produces fine, fragmented flocs.

Q14. O-tank sludge with almost no settleability at very low load

Question: Our influent load is far too low: aerobic influent COD is around 300, treating 1000 m³/day in a 3000 m³ aerobic basin, as shown. The O-tank sludge has almost no settleability. How do we fix this?

Answer: Try stirring a sample with a glass rod to see how it behaves, and check whether gas bubbles are trapped in the sludge. Control dissolved oxygen between 1 and 3; increase return and cut inflow so the effluent does not go turbid. Keep pH around 7, monitor for filamentous organisms, and increase sludge wasting.

Q15. pH crashing from 7 to 3 overnight in a dyeing-wastewater O tank

Question: We treat printing-and-dyeing wastewater: influent COD around 5000, around 10,000 when sulfur black dye comes through; physicochemical dosing removes about half. Next comes electrochemical treatment (equipment just delivered, still being installed and commissioned), then an A tank and an O tank — the A tank is new, a basin cleared out and fitted with a submersible mixer. We feed the O tank intermittently each day; after one night of aeration, pH falls from about 7 to 3. I keep feeding to raise pH back to 7, and the next night it falls to 3 again — this has repeated for about a week. Once the A tank is back in service, will things improve?

Answer: Yes, restore it — the A tank can replenish part of the alkalinity. Increase the internal return to carry alkalinity forward, but alkali dosing will still be needed.

Q16. Green four-cornered spiny organisms seen under the microscope in coking wastewater

Question: During microscopy of our coking wastewater recently, we saw something green with four corners bearing spines and segmented in form. What is it?

Answer: It is Scenedesmus, a genus of green algae (phylum Chlorophyta, class Chlorophyceae, order Chlorococcales, family Scenedesmaceae) and a common component of freshwater plankton. The colony is a fixed coenobium of 2, 4, 8 or 16 — rarely 32 — cells; the cells are elliptic, ovoid, long-cylindrical, fusiform or crescent-shaped. It occurs worldwide in fresh water, living widely in ponds, lakes, ditches, small pools and culture vessels — a common and important planktonic alga that reproduces fast and is nutritious. This one is specifically Scenedesmus quadricauda, the four-tailed scenedesmus.

Q17. CASS: MLSS 3200, SV30 80, clear supernatant, but sludge in the decanter

Question: Our plant runs CASS. For about two months the basin has held MLSS around 3200 with SV30 around 80 percent; the supernatant is very clear and microscopy shows no great filament abundance, yet the decanter's effluent carries sludge. Is this sludge bulking, and what should we do?

Answer: It should be related to bulking, because a clear supernatant with solids in the decanter effluent is a contradiction. What most likely happens is that after filamentous bulking, the activated sludge cannot settle fast enough, part of the biomass leaves the system with the draw-off, and that is the solids you see in the decanter effluent.

Q18. Foam on the aeration tank and rising sludge in the clarifier after DAF upstream

Question: Our train is raw water → equalization → DAF → carrier fluidized bed → activated sludge tank → secondary clarifier. Into the fluidized bed: COD 500, SS 230, conductivity 10720; fluidized-bed DO 0.8; sludge-tank DO 3.2, MLSS 4536, MLVSS 2828. Recently there is much foam on the sludge tank, the clarifier sheds sludge, the water looks reddish and the effluent carries fine sludge. What is the cause, and how do we clear the foam and the sludge rise?

Answer: Once foam (scum) forms, if the sludge concentration in the aerobic tank is falling markedly, that scum is your own activated sludge. The cause is most likely poor performance of the DAF upstream: solids that should have been removed flow into the biological basin and inert matter accumulates in the system. It may also be a change in influent composition shocking the system, disintegrating the sludge, which aeration then lifts to pile up as surface scum.

Q19. SBR under startup hit by COD 8000 and ammonia 440

Question: The SBR plant we are commissioning was hit by influent COD 8000 and ammonia 440. The basin surface floats about 10 cm of foam; repeated adjustments have not helped. Effluent ammonia is above 100 and COD above 100; SV30 runs 80–99 percent, the sludge structure is fine and fragmented, the settling ratio will not come down, and the effluent is turbid at times. The foam is brownish and nothing has improved. Influent is now COD 1100 and ammonia 250–330; normal SV30 for this plant runs 40–70 percent. How do we solve this?

Answer: (1) After a shock, the first job is to remove it — recycle, dilute, increase aeration. (2) Once the shock has been absorbed, the next job is recovery: expel as quickly as possible the pollutants that entered the system, and the key to that lies in the sludge — so increase sludge wasting, which also promotes microbial reproduction and helps the system recover fast.

Q20. Secondary clarifier: sludge settles very poorly and escapes

Question: In our secondary clarifier the sludge settles particularly poorly, and sludge escapes unless wasting is done promptly; SV30 is 50 and sludge concentration over 4000. We are strengthening wasting. The effluent is also turbid — what is the cause?

Answer: (1) Wasting may be due. (2) The hydraulic or organic load may be too high. (3) Aeration may be excessive. (4) Essentially the same as (1): the sludge age has grown too long. (5) The sludge may be bulking. (6) The system may have been shocked or poisoned.

Q21. Oxidation ditch at half design flow: effluent COD rising from 13 to 25

Question: Our plant runs a Carrousel oxidation ditch with influent COD 400 and ammonia 15 at 100 m³ per hour, in a 5000 m³ basin (designed for COD 800 at 250 m³ per hour). Current parameters: DO 1.5–2.2, MLSS 1500, SV30 10; effluent COD 25 and ammonia about 0.1. Recently the effluent COD climbed straight from around 13 to 25, the clarifier effluent carries many suspended solids and looks turbid. I judged it sludge aging and increased wasting for two days running — no effect. What measures do you suggest?

Answer: (1) Stop the heavy wasting. Judged from the influent, the sludge concentration and the settling ratio, the concentration is not especially high, and the flow is less than half of design — so do not over-aerate downstream either. (2) Reduce aeration: at half the design flow with the aerobic stage already discharging well, aeration should be cut — and mind this in operation from now on. As for wasting, the danger is wasting too hard: there is not much sludge to begin with, and performance would collapse at once. Follow the points above. Your situation in one phrase: too many microorganisms chasing too little food — learn to control for that. (3) With sludge concentration this low, do not waste; control DO between 1.0 and 1.5, and while ammonia stays stable and compliant, keep DO as low as practical — the sludge's flocculation will be better for it.