What Is a Sedimentation Tank? Wastewater Treatment Terminology Explained
1. Structure and working characteristics of the horizontal-flow sedimentation tank
To make the incoming wastewater enter the sedimentation tank uniformly and stably, the inlet zone should have flow-straightening measures. The baffle at the inlet generally stands 0.1–0.15 m above the water surface, with a submerged depth of no less than 0.25 m, generally 0.5–1.0 m, and the baffle is 0.5–1.0 m away from the inlet.
The outlet device of the horizontal-flow sedimentation tank.
The effluent weir not only controls the water level inside the sedimentation tank, but also directly affects the uniform distribution of the flow in the tank. The sedimentation tank should have equal overflow per unit length along the entire effluent weir; for primary sedimentation tanks this is generally 250 m³/m·d, and for secondary sedimentation tanks 130–250 m³/m·d. Sawtooth triangular weirs are the most widely used, with the water surface located at 1/2 of the tooth height. To adapt to flow changes or uneven settlement of the structure, adjustable devices that allow the weir plate to move up and down need to be installed at the weir outlet so that the outlet weir crest is as horizontal as possible.
A baffle should be installed in front of the weir to block floating matter, or a scum collection and removal device should be provided. The baffle should be 0.1–0.15 m above the water surface, submerged 0.3–0.4 m below the water surface, and located 0.25–0.5 m from the outlet.
Multiple-hopper sedimentation tanks can omit mechanical sludge scraping equipment. Each sludge hopper is equipped with an independent sludge discharge pipe and discharges sludge independently without mutual interference, ensuring the concentration of the settled sludge. In the width direction of the tank there are generally no more than two rows of sludge hoppers.
The main design parameters of the horizontal-flow sedimentation tank are horizontal flow velocity, sedimentation time, tank depth, tank width, length-to-width ratio, length-to-depth ratio, etc. The key design points are as follows:
(1) The turbidity of the settled effluent should be no greater than 5 NTU when used as chemical water treatment influent, and no greater than 20 NTU when used as cooling water.
(2) The number of tanks or compartments is generally no less than 2.
(3) The sedimentation time is generally 1.0–3.0 h. When treating low-temperature, low-turbidity or high-turbidity water, the sedimentation time should be appropriately extended.
(4) The average horizontal flow velocity in the sedimentation tank is generally 10–25 mm/s.
(5) The effective water depth is generally 3.0–3.5 m, and the freeboard is generally 0.3–0.5 m.
(6) The length-to-width ratio of the tank should be no less than 4:1; the width of each compartment or the spacing of diversion walls is generally 3–9 m, with a maximum of 15 m.
(7) The length-to-depth ratio of the tank should be no less than 10:1. When a sludge suction machine is used for sludge discharge, the tank bottom is a flat slope.
(8) The inlet and outlet forms and their arrangement have a great influence on the effluent performance of the horizontal-flow sedimentation tank. Generally, when a perforated wall is used for water distribution at the inlet end, no holes are provided in that part of the perforated wall from 0.3–0.5 m above the settled sludge level at the tank bottom down to the tank bottom, so as to avoid disturbing the settled sludge. When the flow velocity at the tank outlet is relatively high, finger-shaped troughs can be added in front of the effluent trough to reduce the load on the outlet trough weir.
(9) For freeze protection, an ice cover (suitable for sloped tanks) or cover plates (with manholes and sampling holes) can be used; where conditions permit, waste heat can also be used for freeze protection.
(10) The drain-down time generally does not exceed 6 h.
(11) The Froude number is generally controlled between 1×10⁻⁵ and 1×10⁻⁴.
(12) The Reynolds number in horizontal sedimentation tanks is generally 4000–15000, mostly turbulent flow. The design should pay attention to the placement of partition walls to reduce the hydraulic radius R and thereby lower the Reynolds number.
(13) To save land, large horizontal sedimentation tanks can also be built on top of clear-water reservoirs, but the sedimentation tank must be strictly guaranteed not to leak.
The tank plan is mostly circular, sometimes square. The diameter is large while the depth is small: the diameter is 20–100 m, the water depth at the tank center is no more than 4 m, and the peripheral water depth is no less than 1.5 m. The wastewater enters the tank from the central inlet pipe and flows slowly toward the tank periphery along the radius. Suspended solids settle during the flow and enter the sludge hopper along the tank bottom slope; the clarified water overflows from the tank periphery into the effluent channel.
To avoid short-circuiting, first, measures should be taken as far as possible in the design (such as using suitable inlet distribution devices to eliminate the inlet jet and distribute the flow evenly over the flow section of the sedimentation tank, reducing turbulence and preventing excessive velocity near the sludge zone, using finger-shaped effluent troughs to extend the length of the effluent weir; covering the tank or installing partition walls to reduce the influence of wind and solar heating of the water; pre-settling high-concentration water to reduce density currents caused by high influent suspended solids, etc.); second, operation management should be strengthened: before the sedimentation tank is put into operation, the effluent weir should be strictly checked for straightness, and any problem found should be repaired in time. During operation, floating scum may block part of the overflow weir outlets, causing unequal overflow per unit length of the whole effluent weir and producing flow suction; operators should promptly clean the scum off the weir outlets; sawtooth triangular weirs made of plastic may deform over time, and management personnel should repair or replace them in time to ensure uniform outflow and reduce short-circuiting. Through the above measures, the short-circuiting phenomenon of the sedimentation tank can be reduced to a minimum.
For algae already growing on the inclined plates and tubes, high-pressure water washing can be used; often the attached algae can be removed as soon as washing is carried out. The secondary sedimentation tank of the activated sludge treatment system is an important component of the system. Whether the secondary sedimentation tank operates normally directly affects the effluent quality of the treatment system and the concentration of the return sludge, and has a major impact on the purification effect of the whole system. The operation and management of the secondary sedimentation tank is relatively complex; for common problems and preventive measures during its operation, refer to "Operation and Management of Activated Sludge Treatment Systems".
The sedimentation tank is generally a structure for sludge-water separation before or after biochemical treatment, mostly for separating relatively fine sludge particles. The one before biochemical treatment is called the primary sedimentation tank; the settled sludge contains more inorganic components, and its moisture content is lower than that of the secondary sedimentation tank sludge. The sedimentation tank located after biochemical treatment is generally called the secondary sedimentation tank, which mostly contains organic sludge with a relatively high moisture content.
The hydraulic calculation of the counter-flow inclined tube sedimentation tank can be summarized into the following three types:
The diameter dp of the separable particles can be expressed as:
If expressed by the settling velocity us of the separable particles, then:
Where: Q—sedimentation tank flow rate
μ—particle settling velocity, m/s;
Af—total horizontal projected area of the inclined plates, m;
A′f—actual total area of the inclined plates, m;
θ—inclination angle of the inclined plates, (°);
h—installation height of the inclined plates, m;
v—flow velocity inside the plates, m/s;
L—total length of the inclined tube assembly (equivalent to the tank length), m;
h1—sludge accumulation height (hopper height), m;
h2—water distribution zone height, m;
H—total height of the sedimentation tank, m;
t—time required for particle settling, s;
The relationship between the separable settling velocity usc obtained from the least favorable cross-section for sedimentation and us is: usc=us, where s is a constant. The S value is called the characteristic parameter of the inclined tube, determined by the cross-sectional shape.
The counter-flow inclination angle needs to be maintained at 45-60°.
Differences in the layout of inclined tube sedimentation tanks will affect the selection of the design interception velocity. For larger inclined tube sedimentation tanks, it is not easy to ensure uniform inlet distribution and outlet collection, so indicators lower than those of smaller inclined tube sedimentation tanks should be selected in the design. In the design of counter-flow inclined tube sedimentation tanks, the interception velocity is generally 0.15-0.40 mm/s.
Domestic counter-flow inclined tube sedimentation tanks almost all use a regular hexagonal cross-section, generally using the inscribed circle diameter as the tube diameter; for water treatment, the tube diameter of counter-flow inclined tube sedimentation tanks is 25-35 mm.
The inclined tube length should generally not be less than 50 cm; the length of the inclined tube depends on its fabrication and the depth of the sedimentation tank.
The following parameters are needed to design an inclined tube sedimentation tank:
Counter-flow velocity 8.3-14 mm/s.
The Reynolds number (Re) in ordinary horizontal-flow sedimentation tanks is often above 10⁴, and the flow belongs to turbulent flow. Inclined tube sedimentation tanks, because of the increased wetted perimeter and reduced hydraulic radius, have a significantly reduced Reynolds number (Re), so that they can be fully controlled under laminar flow conditions (Re below 500).
In horizontal-flow sedimentation tanks the Fr value is roughly on the order of 10⁻⁵. Inclined tube sedimentation tanks, due to the reduced hydraulic radius and increased flow velocity, generally have Fr numbers in the range of 10⁻³-10⁻⁴, so the flow stability is significantly increased.
The basic requirement of sedimentation tank operation management is to ensure that all equipment is safe and in good condition, to adjust the various operating control parameters in time, and to ensure that the effluent quality meets the specified indicators. To this end, the following aspects of work should be emphasized.
When the sedimentation tank is used for liquid-solid separation in the coagulation process, correct coagulant dosing is one of the keys to sedimentation tank operation management. To dose the coagulant correctly, changes in influent water quality and quantity must be mastered. Taking drinking water purification as an example, the turbidity, pH value, water temperature and alkalinity of the raw water are generally measured once every 2-4 hours. In seasons with frequent water quality changes, a measurement is required every 1-2 hours to understand the start-stop status of the influent pump house, and the dosing rate should be adjusted in time according to changes in water quality and quantity. In particular, dosing interruption accidents must be prevented, because even a short period without dosing will lead to deterioration of the effluent quality.
Timely sludge discharge is an extremely important task in sedimentation tank operation management. The sedimentation tanks in wastewater treatment contain a large amount of sludge, most of which is organic. If the sludge is not discharged in time, anaerobic fermentation will occur, causing the sludge to float up, which not only destroys the normal operation of the sedimentation tank but also deteriorates the effluent quality, such as a rise in dissolved BOD in the effluent and a drop in pH. The sludge discharge cycle of the primary sedimentation tank should generally not exceed 2 days, and that of the secondary sedimentation tank should generally not exceed 2 hours. When sludge discharge is not thorough, the tank should be stopped (emptied) and cleaned by manual flushing. Sedimentation tanks with mechanical sludge discharge require strengthened maintenance and management of the sludge discharge equipment; once the mechanical sludge discharge equipment fails, it should be repaired promptly to avoid excessive sludge accumulation at the tank bottom affecting the effluent quality.
In sedimentation tanks for water treatment, when the raw water has a high algae content, algae will breed in the tank, especially in regions with higher temperatures; when inclined tubes are installed in the sedimentation tank, this phenomenon may be more prominent. Although algae growth will not seriously affect the operation of the sedimentation tank, it is detrimental to the effluent quality. The preventive measure is to add chlorine to the raw water to inhibit algae growth. Using ferric chloride coagulant also has an inhibitory effect on algae.