Water Sample Testing of Landfill Leachate Wastewater

2026-10-16 10:39:58
立即下载

Water Sample Testing of Landfill Leachate Wastewater

I. Purpose of the experiment

To test the water sample and evaluate the COD removal effect after the experiment.

II. Experimental procedure

(1) The water sample was subjected to catalytic oxidation aeration for 60, 100, 140 and 180 min, and samples were taken to measure the water sample COD.

III. Test results

sinokle

Ozone dosage (min)

COD (mg/L)

COD removed (mg/L)

COD removal rate (%)

Water sample

2715

——

——

60

2095

620

22.83%

100

1895

820

30.20%

140

1610

1105

40.69%

180

1570

1145

57.83%

sinokle

IV. Experimental conclusions

(1) After catalytic oxidation of the water sample, at 180 min of ozone aeration the water sample COD was 1570 mg/L, a reduction of 1145 mg/L.

(2) After 140 min of aeration, the COD removal effect of the water sample declined noticeably.